The hazard of the refrigerating oil in the new energy vehicle drive motor test system increases the condensation temperature and the condensing pressure; the condenser heat transfer deteriorates. Because the oil film produced by the oil entering the condenser has a thermal conductivity much smaller than that of the metal, the thermal resistance is increased and the heat transfer coefficient is reduced. The refrigeration oil in the new energy vehicle drive motor test system reduces the evaporation temperature and the evaporation pressure, and the compressor cooling capacity decreases, and the unit power consumption increases, making it difficult to cool down the cold. There are two reasons for this. On the one hand, it is consistent with the cause of the condenser; on the other hand, due to the accumulation of oil in the evaporator, the effective area of the evaporator is reduced.

The refrigeration oil in the new energy vehicle drive motor test system is prone to blockage, causing the system to work abnormally. This is mainly due to the high viscosity of the oil, which is easy to mix with dirt and mechanical impurities into a gel-like substance. When the gel-like substance accumulates in a pipe or valve with a small cross section, it is easy to cause blockage and cause refrigeration conditions. disorder. In order to avoid and reduce the entry of oil, the new energy vehicle drive motor test system, in addition to setting the oil separator with good performance and correctly grasping the fuel quantity of the compressor, the regular oil discharge work of the refrigeration equipment must be done during operation. In addition, you should also pay attention to the balance between the amount of oil added and released. If it is found that the amount of fuel added to the compressor is increased and the amount of oil released is reduced, the cause should be eliminated in time and the number of times of oil discharge should be increased to prevent excessive oil from entering the refrigeration system.
The impact of the refrigeration oil in the new energy vehicle drive motor test system is self-evident. It is recommended that the new energy vehicle drive motor test system adopt a fully enclosed circulation pipeline so that oil mist and refrigeration oil and other faults will not occur during operation.
Похожие рекомендации
-
Exhibition Preview | 2019 China International Automotive Testing Quality Monitoring Expo
1214Autumn is cool, the exhibition season is here again!For you to present Wuxi Guanya LNEYA exhibition information: We invite you to attend:2019 China International Automotive Testing and Quality Control ExpoExhibition time: September 24-26Exhibi...
Посмотреть детали -
Как влияет небольшой чиллер с водяным охлаждением на промышленное производство?
1166Небольшой чиллер с водяным охлаждением используется в самых разных областях, например, в пищевой и фармацевтической промышленности. В некоторых областях промышленности часто требуются небольшие чиллеры с водяным охлаждением. Применение ...
Посмотреть детали -
Fully closed cycle high viscosity fluid refrigeration heating flow control system
942Application:1. The tested object is connected to a test platform adapter.2. The internal parts of the parts are cooled, heated, flow controlled, and pressure controlled by various lubricating oils, hydraulic oils, aviation fuel, fuel oil, and co...
Посмотреть детали -
Development Of LNEYA Low Temperature Chiller
956With the internationalization of the economy, Wuxi Guanya has seized the opportunity. It not only develops rapidly in China, but also actively develops foreign markets, and becomes one of the important enterprises in the development of low tempera...
Посмотреть детали