Leakage Detection Tips of Low Temperature Freezer
Pressure leaking detection
It is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The leakage detecting pressure of high-pressure system is 1.25 times greater than designing condensing pressure, while that of the low-pressure system is near 1.2 times higher than saturation pressure in condition of the temperature in summer. With it, refrigerating plant can stop from leakage no matter it is working or parking. Some cooling system should be detected according to the provisions of the pressure if there is a predefined acceptance or leakage detection standard. Obviously, the leakage detecting pressure can not be raised casually, otherwise it is likely to destroy the equipment, resulting in an accident.
Bubble test
It is a widely used detecting method at present , especially for those medium and large freezer systems that take advantage of it to search for the leak point. Generally, bubble test is comprised of soap or soap powder. The solution of soapy water should not be too ropy; if not, the viscosity will be too big to flow, worsening the sensitiveness of the test. But as an editor of Whose Low Temperature Freezer Is Best,i would like to tell you that the modulation not ought to be too dilute, or else the fluidity will be too large to be adhere to the surface of the equipment, being hard to form the bubbles. The soapy water can be applied the leaky point with hairbrush directly to observe whether this position is blistering. When it comes to the positions that are difficult to observe straightway, mirror reflection and flashlight can be used. After the test, the soapy water should be dried up in case of corrosion.
LNEYA have more freezers for sale and low temperature freezer price is really affordable.
Похожие рекомендации
-
LNEYA охлаждение и нагрев термостат ванна инструкция
1398Circulating thermostatic water bath is water circulation and cooling function based on the increase in the water bath, can improve the precision of temperature control and temperature stability, can be widely used for drying, distillation, concent...
Посмотреть детали -
Использование аккумуляторных охладителей электромобилей в прикладной промышленности
1231В индустрии электромобилей аккумуляторная батарея является одним из основных компонентов, с высокой сложностью и комплексным характером, поэтому выбор охладителя для ее тестирования также очень важен. Охладитель аккумулятора электромобиля LNEYA обеспечивает решение...
Посмотреть детали -
Precautions for the use of LNEYA chillers in industrial processes
12211. Installation (check the machine for damage, choose the right location for installation and maintenance) 2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the wor...
Посмотреть детали -
What are the main hazards of the reaction kettle in the reactor intelligent temperature control syst
1160The intelligent temperature control system of the reactor is used in various chemical fines. With the constant attention of the industry safety issues, some risk factors of the intelligent temperature control system of the reactor should be avoide...
Посмотреть детали