Метод соединения реакционного чайника и электрического шкафа управления реакционным оборудованием
The supporting equipment of the reaction kettle is the temperature control product provided by our company for the majority of users for the users. When the user selects the equipment for the reaction kettle, it is necessary to understand the connection between the reaction kettle and the electric control cabinet.
The connection method of the reaction kettle and the electric control cabinet in the auxiliary equipment of the reaction kettle, the signal transmission line of the electric control cabinet system is connected with the temperature sensor on the reaction kettle body, the connection with the heating system switch cabinet and the three-way valve, and the oil supply pipe and The oil pump on the oil return pipe is connected; the electric control cabinet of the auxiliary equipment of the reaction kettle is connected with the power source; the oil supply pipe outputted by the heating system and the cooler output oil pipe are connected through the three-way valve, and the three-way merge valve outlet and the reaction kettle inlet pipe pass through the pipe The road connection; the circulating oil pump is arranged on the oil return pipe; the charge pump is arranged on the oil filling pipe between the oil storage tank and the expansion oil tank.
The electric control cabinet of the auxiliary equipment of the reaction kettle is to assemble the switchgear, measuring instrument, protective electric appliance and auxiliary equipment in the closed or semi-closed metal cabinet or the screen according to the electrical wiring requirements. The arrangement should meet the requirements of the normal operation of the power system. Maintenance control cabinet (box) that does not endanger the safety of the person and surrounding equipment. Including (distribution cabinet) (distribution box) (electrical control cabinet), etc., the circuit can be switched on or off by manual or automatic switch during normal operation. In the event of malfunction or abnormal operation, the circuit or alarm is cut off by means of a protective device. The measuring instrument can display various parameters during operation, and can also adjust some electrical parameters to prompt or signal the deviation from the normal working state.
The electrical part of the LNEYA reactor is also very important. Users need to understand the electrical part to avoid self-operation, so as to avoid the failure of the equipment of the reactor.
(This article source network, if there is infringement, please contact LNEYA to delete, thank you!)
Похожие рекомендации
-
The Importance of Electric Vehicle Battery Testing Chillers
1552The Importance of Electric Vehicle Battery Testing Chillers
Посмотреть детали -
The Main Application Areas of Air Cooled Chillers
1884Inthe domestic and international industrial water chiller market, our most commonindustrial water chiller equipment can be roughly divided into two differenttypes, one type is industrial air cooled chiller, the other type is industrialwater co...
Посмотреть детали -
Как справиться с утечкой хладагента при переработке органических отходов?
1805В процессе обработки органического отработанного газа, если обнаруживается утечка хладагента, рекомендуется своевременно ее устранить. Профессиональный производитель LNEYA по переработке органических отходов анализирует знания о переработке органических отходов...
Посмотреть детали -
How to purchase a power management chip temperature test system?
1898The power management chip temperature test system is an important equipment used to test the performance and reliability of semiconductor chips in different temperature environments. When purchasing this type of test equipment, you need to...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик










