Factors affecting cooling capacity during temperature control of battery test equipment
Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher the cooling capacity, the lower the water temperature, the smaller the cooling capacity. Battery test equipment pump power water circulation amount, directly affects heat transfer speed, evaporator, condenser form, divided into water tank coil test, shell tube type, stainless steel plate type, etc., we need to configure according to certain requirements, thermal material Medium copper tube heat transfer is better.
There are also external factors affecting the cooling capacity of battery test equipment. Most of the battery test equipment is air-cooled. Therefore, the external ambient temperature needs to be within a reasonable range. The condensation temperature should not exceed 45 degrees. Once the cooling capacity is exceeded, it will be significantly weakened. Can not be too low, the battery test equipment air is also very important for convection, the vents can not have a barrier, reference to the standard outlet vents can not have obstacles within 1 meter.
The cooling capacity of the battery test equipment is related to the operation process of the entire battery test equipment. Therefore, the cooling capacity of the battery test equipment must be guaranteed, so that the battery and the motor operate well in the process of cooling and heating.
Похожие рекомендации
-
LNEYA star refrigeration heating system SUNDI-320/420W/430W
1868Today, I will introduce the model of LNEYA's refrigeration heating system: SUNDI-320/420W/430W. It has three kinds of medium temperature range: -30°C~180°C; -40°C~180°C; -40°C~200°C. The control system is programmed to program up to 10 programs...
Посмотреть детали -
The benefits of choosing a cryostat
2195The temperature of the effluent of the cryogenic refrigerator is very low, so the carrier medium can not be used for water (the water will freeze when it reaches 0 ° C). At this time, it is necessary to use a brine solution or a glycol solution, a...
Посмотреть детали -
What are the main points for regular maintenance of the recirculating chiller?
1462Recirculating chillers are used frequently in the industry, and the heat generating parts of various devices require recirculating chillers, so operating efficiency is very important. During the running time of the recirculating chiller, it is nec...
Посмотреть детали -
Выбор модели термостата TCU и описание технических параметров
2199Система контроля температуры TCU также представляет собой двухцикловую систему контроля температуры с одним потоком жидкости. При выборе модели очень важна вся реакция термостатирования. Только соответствующая реакционная система используется для экзотермы и поглощения...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик