Как справиться с сигналом неисправности оборудования рециркуляционного охладителя
What to do if there is a failure and alarm
during the use of the recirculating chiller equipment? In order to ensure
production, such problems need to be resolved quickly.
We must first understand the causes of
failures and alarms, and adopt different solutions for different causes. Common
recirculation chiller equipment failures and alarms include reverse phase
alarm, contactor jam alarm, over-temperature protection alarm, abnormal
pressure alarm, overload alarm, etc. No matter what kind of fault alarm, it can
be known according to the alarm light and alarm signal information.
1. Recirculation chiller equipment reverse
phase alarm
When a reverse phase alarm occurs in the recirculation chiller
equipment, the circulating pump cannot be started. There are two reasons for
the reverse phase alarm of the high and low temperature cold water circulation
device. One is that the phase sequence of the three-phase power line is
connected incorrectly, and the other is that the reverse protector fails. If
the phase sequence of the three-phase power cord is connected incorrectly, just
adjust the phase sequence directly. If the reverse phase protector fails, it
needs to be replaced.
2. Contactor stuck alarm
Recirculation chiller equipment contactor
stuck alarm, the over-temperature indicator will also be on, generally there
are three reasons: one is the heating AC contactor stuck, the other is the
computer board heating has been outputting, there is a problem, and the third
is the over-temperature The protection switch operates incorrectly. When the
contactor is stuck and alarms, the continuous heating of the heat transfer oil
will cause danger, so deal with it in time.
3. Alarm for lack of media
In order to protect the heating pipe and circulating pump of the
recirculating chiller equipment, the system will stop heating when there is a
shortage of media. When there is a lack of media, check whether there is a lack
of media (water or oil). If the water temperature meter shows that there is a
lack of media, you can adjust the pressure value of the pressure switch to a
lower value.
4. Overload alarm
When the recirculation chiller equipment has an overload alarm,
check whether the circulating pump is overloaded. If the pump is overloaded,
you can increase the overload current ampere.
When the recirculation chiller equipment
fails and alarms, as long as it is dealt with in time, there will be no safety
issues. LNEYA is a manufacturer of recirculating chiller equipment, equipped
with an after-sales service system. For minor problems such as fault alarms,
you can consult us sales@lneya.com for a faster and safer solution.
Похожие рекомендации
-
Многофункциональная высоко- и низкотемпературная камера испытания на удар качественный элемент цена
1179Особенно при покупке многофункциональных высоко- и низкотемпературных камер для ударных испытаний ценовой фактор часто определяет качество продукции. В конце концов, производителям нужно выживать. Вряд ли они будут продавать высококачественные экв...
Посмотреть детали -
Lneya’s high and low temperature cooling circulator instructions
1102The high and low temperature cooling circulator is developed and produced by LNEYA using its refrigeration and heating temperature control technology. When using high and low temperature cooling circulators, users are advised to use them according...
Посмотреть детали -
How to choose the lubricant for the injection molding machine?
1393The injection molding machine cooling system lubricating oil needs to pay attention to the type of compressor when selecting. The compressor has three types: piston type, screw type and centrifugal type. The first two kinds of lubricating oil are ...
Посмотреть детали -
Maintenance of the condenser of high and low temperature circulation device
1187The condenser in the high and low temperature constant temperature circulation device is one of the accessories in the refrigeration process, and its performance is very important. LNEYA reminds the user that regular maintenance is required after ...
Посмотреть детали