Какой блок охлаждения совместим с жидкостным охлаждением в центре обработки данных?
Data center liquid cooling usually matches a variety of cooling equipment to achieve efficient heat management and ensure that servers and IT equipment operate within a safe operating temperature range.
Cooling unit for data center liquid cooling:
Cold Plates: directly attached to the CPU, GPU and other heat-generating components of the server, and remove heat through liquid cooling medium.
Immersion Cooling System: directly immerse the server in non-conductive coolant, and exchange heat through direct contact with the liquid, which is suitable for high-density computing environments.
Indirect Contact Liquid Cooling System: heat is exchanged with the coolant inside the server through an intermediary fluid (such as fluorinated liquid) in a heat exchanger outside the server, and then the intermediary fluid is transferred to the external cooling system.
Coolant Distribution Unit (CDU): responsible for the circulation, filtration, pressure control and possible temperature regulation of the coolant, and is the core component of the liquid cooling system.
Heat Exchanger: used to transfer the heat in the coolant to the external cooling medium, such as water or air, including plate, tube or mixed heat exchangers.
Cooling Tower or Dry Cooler: located at the end of the liquid cooling system, used to discharge the accumulated heat in the heat exchanger to the atmosphere, or complete the heat exchange through the air cooling medium in the dry cooler.
Circulation Pump: promotes the circulation of coolant in the system to ensure the efficiency of heat exchange.
Water Treatment System: used to treat and maintain the purity of the coolant to avoid corrosion and microbial growth.
In summary, whether it is liquid cooling or traditional air cooling system, the selection and configuration of data center cooling equipment are determined by comprehensive consideration of factors such as the scale of the data center, energy consumption requirements, regional climate conditions and business needs.
Data Center Liquid Cooling ChillerCold Plate Cooling or Immersion Cooling
Блок распределения охлаждающей жидкости (CDU) / охладитель
For Servers Cooling/Rack Cooling CDU will become the mainstream thermal solution in the data center. In general, cooling systems with radiators, fans, air conditioning units, etc. are considered insufficient for CPUs over 300W. To cont…
загрузка...
已经是到最后一篇内容了!
Похожие рекомендации
-
How to control the emulsification temperature of the emulsifier?
986A good cream product is not only reflected in the quality of raw materials, but also has a great influence on the emulsification process during production, such as the texture and stability of the product, and the temperature control during produc...
Посмотреть детали -
High and low temperature integrated machine equipment blockage instructions
967If the high and low temperature integrated machine equipment is running for a long time, if it is not taken care of, it may cause the high and low temperature integrated machine equipment to be blocked. How to solve the equipment blockage? The fir...
Посмотреть детали -
Precautions for safe use of heat transfer oil temperature control equipment
1023With the extensive use of thermal oil temperature control equipment, the safe use of thermal oil temperature control equipment is a concern for users. For manufacturers, it is very important to share the precautions for the use of thermal oil temp...
Посмотреть детали -
Особенности и применение охладителей с вакуумным радиатором
716Вакуумные охладители теплоотводов - это тип оборудования, специально разработанный для обеспечения охлаждения в условиях высокого вакуума, и обычно используется в научных исследованиях, производстве полупроводников, аэрокосмической промышленности и других областях, где требуется высокая...
Посмотреть детали