General high and low temperature integrated machine valve repair detailed description
The conventional high and low temperature integrated machine valve replaces the packing, and the main function of the packing is to prevent the working medium from leaking along the axial direction of the valve stem. In case of minor leakage, the packing gland can be tightened. If the leak cannot be eliminated, the packing should be replaced. When replacing, the valve stem must be screwed out to the end. Use the filler needle to pull out the old packing, then screw the prepared new packing in turn, and then tighten the gland.
In conventional high and low temperature integrated machine engineering, the valve core of a large diameter valve is sealed by a layer of babbitt or fluoroplastic. The back of the spool also has a layer of babbitt so that when the stem is rotated out of position, the working fluid can be sealed without leaking outward along the stem. After the valve is disassembled, first straighten the stem to deburr, then replace the valve’s babbitt alloy. At the same time, the valve seat should also be ground to make the valve core and the valve seat tight. For small cast steel or brass valve spools, the seal of this valve is obtained by a line of metal contact, hence the line seal. Because it is a wire seal, the valve seat and the valve core should be carefully ground to obtain a satisfactory sealing effect. After the valve is overhauled, the air tightness test shall be carried out in accordance with the relevant requirements.

The repair of the safety valve in the explosion-proof high-temperature integrated machine refrigeration system is also roughly the same as above, but since the babbitt alloy is soft, it is often difficult to return to the original position after the safety valve is operated once due to overpressure, so when the pressure is reduced to the closing pressure At the time, it is still not tight. In order to overcome this drawback, some products have changed the Babbitt alloy to a nickel-chromium-titanium (harder) alloy, or replaced with polytetrafluoroethylene.
The timely maintenance of conventional high and low temperature integrated machine valves can better help the operation of conventional high and low temperature integrated machines, so it is recommended to solve them in time.
Похожие рекомендации
-
Разница между большим холодильным и нагревательным циркулятором и испытательной камерой
9241. Для высокотемпературного испытания при особых обстоятельствах высоко- и низкотемпературная испытательная камера может не соответствовать требованиям. Вообще говоря, верхний предел высокой температуры высоко- и низкотемпературной испытательной камеры составляет 200 ℃, а ее ...
Посмотреть детали -
Instructions for using the hydrogenation reactor cooling and heating integrated system
1219There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
Посмотреть детали -
Описание общих неисправностей полупроводникового холодильного агрегата LNEYA
1412If a high-voltage alarm occurs in the semiconductor refrigeration unit, it is necessary to check whether the external piping is blocked or dirty. Clean and remove in time. If it is an air-cooled semiconductor refrigeration device, it is necessary ...
Посмотреть детали -
Как продлить срок службы гликолевой системы охлаждения?
1017In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points: 1. Use automobile grade antifreeze carefullyDo not use automobile grade or unqualified antifreeze. Because this gl...
Посмотреть детали