Laboratory chiller refrigeration temperature control system equipment
Lab water chillers, as the name implies, are mainly used in colleges and universities, scientific research and laboratories. Specially for the cooling of small laboratory equipment such as spectrometer, mass spectrometer, viscometer, rotation, fermentation device, a rotary evaporation apparatus, etc. to make them work under the suitable working temperature.
Could them only be used in this way? In fact, the lab water chillers are also called small chillers. It can also be used for cooling with small instruments or small power equipment. For example:
1. Vacuum pump and medical equipment: molecular pump, diffusion pump, cooling blanket, X-ray machine, nuclear magnetic resonance, accelerator;
2. Industrial equipment and other: laser equipment, vacuum coating equipment, biological pharmacy, mold, machine tool, vacuum furnace, welding machine, reaction kettle.
3. Matched small vacuum pumps, such as molecular pumps, oil and gas recovery pumps, small roots pumps, rotary disc pumps, slide valve pumps, etc. It has the advantages of convenient connection, simple operation, stable temperature, and saving water and electricity, providing a stable temperature environment for the vacuum equipment, and providing the operating efficiency of the equipment.

Laboratory chillers belong to LNEYA refrigeration temperature control system equipment.
Advantages and functions of temperature control system of refrigeration:Temperature range from 120 to 350, performance superior, unique, high – precision, intelligent temperature control.High cooling power from 0.5 to 1200kW, highest production stability and repeatable results.Multi-function alarm system and safety function, use plate heat exchanger, tube type heater to increase heating and cooling rate.
No heat conduction medium evaporates at high temperature, and it can be achieved -80 ~ 190 degrees, -70 ~ 220 degrees, -88 ~ 170 degrees, -55 ~ 250 degrees, -30 ~ 300 degree continuous temperature control without pressurization.The principle and the function has many advantages to using staff: because only expansion of cavity in the body heat conduction medium contact with oxygen in the air (and expansion tank temperature at room temperature to 60 degrees), can achieve lower heat conduction medium absorbed by oxidation and the risk of air moisture.
Похожие рекомендации
-
Working principle of reaction kettle refrigeration system
1067Reactor refrigeration systems are widely used in industry, so basically speaking, reactor refrigeration systems are mostly used in industry. In seasons with high ambient temperatures, the usage rate will be higher. By understanding the operation ...
Посмотреть детали -
Daily Maintenance Tips For Ultra Low Temperature Recirculating Chillers?
1014To ensure normal operation of the ultra low temperature recirculating chillers after startup, it must be ensured that the condenser of the ultra low temperature recirculating chiller has good heat dissipation, otherwise the high temperature protec...
Посмотреть детали -
Система термомасла для реакторов в химической/промышленной лаборатории
1020Термомасляная система для реактора - это система теплопередачи, предназначенная для обеспечения точного и контролируемого нагрева или охлаждения химического или промышленного реактора. В этой системе используется теплоноситель, как правило, высокотемпературный минерал...
Посмотреть детали -
Этиленгликолевая холодильная установка произвела мощное наступление и создала бренд LNEYA за 12 лет
1344Позиционирование с улучшенными характеристиками При выполнении реакции охлаждения и нагрева во многих случаях хладагент не может сам охладить охлаждаемый объект. Поэтому необходим хладагент (или хладагент) для охлаждения холодильной системы в ре...
Посмотреть детали