Precautions for the use of LNEYA chillers in industrial processes
1. Installation (check the machine for damage, choose the right location for installation and maintenance)
2. The location of the installation unit must be the floor, mounting mat or foundation, the level is within 6.4mm, and can withstand the working weight of the unit.
3. The equipment should be placed in the equipment room at a temperature of 4.4-43.3. There should be enough space around the equipment and above for routine maintenance work.
4. Space should be left at one end of the unit to clean the tubes of the condenser tubes. Door openings or other suitable openings can also be used.
5. Select the water pipe with the proper diameter of the pipe, the cooling system and the cold water system running at the maximum power of the equipment, and then connect them correctly.
6. For normal use, the flow rate of the evaporator and condenser is allowed to be between 1.0 and 3.6 m / s.
7. Under any load conditions, the water flow should be stable.
8. In order to use the chiller cost-effectively, we recommend that water treatment experts analyze the water quality of the evaporator and condenser water supply. Poor quality can cause dirt to affect heat transfer, or corrosion and precipitation and growth of organic matter, affecting unit performance and increasing operating and maintenance costs.

Похожие рекомендации
-
What are the system components of various distillation devices?
8321. A complete set of short-path distillation equipment: including short-path evaporator, heating system, feeding system, cooling system, vacuum system, material collection unit, etc.; 2. A complete set of thin film distillation equipment: includin...
Посмотреть детали -
Причина сигнализации высокого давления встроенного блока управления температурой TCU
1009При использовании встроенного блока управления температурой TCU необходимо детально соблюдать инструкцию. При возникновении проблем их необходимо своевременно устранять. Как правило, если мы сталкиваемся с сигналом высокого давления из...
Посмотреть детали -
The role of chiller in the manufacturing process of catalytic materials
983In the field of new material preparation, by accurately controlling the reaction temperature, the influence of different temperatures on the microstructure and macroscopic properties of materials can be explored, thereby developing new mat...
Посмотреть детали -
Описание метода обслуживания машины с холодной и горячей температурой одной пресс-формы
1236В процессе использования горячих и холодных интегрированных температурных машин для пресс-форм, необходимо регулярно проводить техническое обслуживание и ремонт. Затем, LNEYA поделится с вами методом обслуживания горячей и холодной интегрированной машины температуры формы...
Посмотреть детали