Работа испытательной камеры при высокой и низкой температуре влажности
Applicable to aerospace products, information electronic instruments and meters, materials, electrician, electronic products, all kinds of electronic vitality in high and low temperature or hot and humid environment, test its performance indicators
Performance characteristics:
1. It has wide temperature control range, which can meet the needs of users.
2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control can be carried out;The temperature is displayed by touch screen, easy to read, precise and convenient.
3. The temperature error can be adjusted to meet your more accurate test conditions.
4. It has the function of automatically selecting the running refrigeration circuit with the setting of temperature, and the operation is simple.
5. The box door is equipped with a large observation window, which can observe the test status of the test sample at any time.
6. with functions of high temperature on, can be in when the temperature in the oven to 100 ℃, can open the refrigerator, facilitate continuous round-trip experiment was carried out between the high temperature and low temperature.
7. It has the functions of self-diagnosis, overload protection of refrigerator, high pressure switch, overload relay, thermal protection device, etc., to ensure the safety of use.
8. Use a multi-wing fan to circulate the wind in a strong way to avoid any dead Angle, so that the temperature can be evenly distributed in the test area.
9. Wind circulation is designed with wind return wind. The wind pressure and wind speed are in accordance with the test standard.
10. Temperature rise, cooling and system complete independence can improve efficiency, reduce test cost, increase life span and reduce failure rate.
11. The water tank is placed on the side of the unit, and there is water shortage and automatic protection, so as to facilitate the operator to replenish the water supply.
12. The humidification system pipeline is separated from the control circuit board, which can avoid the failure of water leakage in the humidified pipeline and improve the safety.
13. The system of waterway system is opened by door, which is convenient for maintenance and maintenance.
14. In refrigeration system, air cooling or water cooling is adopted in condensation.

Похожие рекомендации
-
Меры предосторожности для клиентов, устанавливающих криогенные промышленные охладители Lneya
1239Первое. При установке низкотемпературных промышленных чиллеров необходимо обратить внимание на некоторые требования к монтажу. 1. Криогенный промышленный чиллер должен быть установлен непосредственно в горизонтальном положении, не устанавливайте его вверх ногами или диа...
Посмотреть детали -
Для какого процесса в производстве полупроводников требуется многоканальный охладитель? Почему он необходим?
1005Химическое осаждение из паровой фазы (CVD): В процессе CVD многоканальный охладитель используется для охлаждения стенок реакционной камеры, теплообменников и теплообменников предварительного нагрева газа для поддержания стабильной температуры в реакционной камере, обеспечивая точный контроль...
Посмотреть детали -
Chip temperature control device selection instructions
1088With economic development and technological advancement, chip temperature control equipment has been developed by the chip industry. LNEYA, as a chip temperature control equipment manufacturer, also guarantees one of the performance and quality as...
Посмотреть детали -
Principle of TCU temperature control system
1363Use area: can be used in various explosion-proof areas The temperature control unit (TCU) is mainly used in reactor heating, cooling temperature control in fine chemical, chemical pharmaceutical, and biopharmaceutical processes. It can realize aut...
Посмотреть детали