Как выбрать охладитель и машину для литья под давлением?
A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
We are a top chiller manufacturer. Welcome to buy our products.
Похожие рекомендации
-
Current status of hot and cold rapid temperature change test chamber
1040At present, manufacturers of hot and cold rapid temperature change test chambers are sprouting like spring bamboo shoots, but there are several manufacturers that really grasp the quality. When purchasing a test box, the buyer must first look at t...
Посмотреть детали -
Как справиться с неисправностью промышленной системы охлаждения воды?
1192Что не так с промышленной системой охлаждения воды, когда она не может охладить? Позвольте LNEYA объяснить вам это ниже: Одной из причин является то, что при первоначальном использовании системы охлаждения жидкости не удается снизить температуру, или что-то не так с ...
Посмотреть детали -
Development prospect of temp measurement and temperature control device for microfluidic chip system
1384With the continuous development of China's science and technology, there has been great progress in the field of integrated circuits and chips. The temperature measurement and temperature control devices in the LNEYA microfluidic chip system have ...
Посмотреть детали -
Immersion phase change liquid cooling system
1154What is immersion phase change liquid cooling system?
Посмотреть детали