Performance Characteristics of 30 HP Water Cooled Chiller
The 30p water cooled chiller is an industrial water chiller with a horsepower of 30 HP. The water-cooled industrial water chiller must rely on the cooling water tower for work, while the air-cooled industrial water chiller uses its own fan for cooling, which has some requirements for the environment: for example, ventilation, humidity and temperature cannot be higher than 40 ℃, air pH value, etc.

Performance characteristics of 30p water-cooled industrial chiller:
1. The primary effect filter is set inside to ensure the heat exchange effect of the heat exchanger and prolong the service life of the heat exchanger.
2. Wide operating range, high temperature control accuracy and energy consumption saving.
3. Special microcomputer automatic control, easier operation.
4. Independent working circuit, energy saving and high efficiency.
5. Shell and tube evaporation heat exchanger is adopted, which has high efficiency, good stability, convenient maintenance and simple operation.
6. The protection function is complete, safe, reliable and durable.
7. Continuous capacity control can effectively improve the energy efficiency ratio of the unit and reduce the operation cost.
8. The product has complete specifications and wide selection range, which is suitable for all kinds of comfortable and process places.
9. Compact design, small volume, light weight, small floor area and small installation and maintenance space.
10. During operation, the load can be adjusted according to the load, and the efficiency of partial load operation is higher.
The industrial chillers independently developed and produced by our LNEYA not only have 30HP, but also have more choices. Different working conditions require different models. If you have questions or purchasing needs, please contact us at sales@lneya.com.
Похожие рекомендации
-
Описание испытаний воздушной системы полупроводникового холодильного отопительного цикла
983В системе охлаждения и нагрева циркулирующего воздуха для полупроводников существует множество элементов тестирования. Сколько же пользователи знают о внеканальном тестировании? Внеканальный тест системы охлаждения и нагрева циркулирующего воздуха для полупроводниковых...
Посмотреть детали -
What are the common debugging problems in low temperature refrigeration baths?
1409When the low-temperature cooling bath is in debugging, if the local cooling effect is not good, the system may be blocked by foreign matter or the system design is unreasonable and cannot be adjusted normally. At this time, LNEYA removes foreign m...
Посмотреть детали -
How to replace the scroll compressor of the impact tester model?
1501In terms of different impact tester models, the configuration is also somewhat different. Among them, special care should be taken when replacing the scroll is a compressor. If the replacement is not noticed, the impact tester cannot be used. The ...
Посмотреть детали -
How to avoid operational errors in fluid heat transfer temperature control systems?
1007During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes. 1. The operation of the fluid heat trans...
Посмотреть детали