Большой охладитель воды

  • High Performance and Low Noise

These compressors not only perform excellently but also operate quietly. Even during long-term operation, they can run for over 100,000 hours without failure.

  • Intelligent Temperature Control

The unit features segmented or stepless energy regulation. It adjusts flexibly according to the thermal load requirements during production, ensuring optimal cooling efficiency.

  • Energy-Efficient Control

By using the outlet temperature of the refrigerant as a control point, the unit’s control center adjusts the compressor load by controlling the movement of the energy regulation valve, achieving actual energy savings.

наружные охладители

Мощность нагрева 3,5 кВт ~ 15 кВт

точность температуры ±0,3℃

большие водоохладители

Мощность нагрева 2,5 кВт ~ 10 кВт

точность температуры ±0,3℃

винтовые водоохладители

Циркуляционный насос MAX 5м³/ч~28м³/ч 2бар

точность температуры ±0,5℃

винтовая холодильная установка

Циркуляционный насос MAX 2,4 м³/ч~12,1 м³/ч 2 бар

точность температуры ±0,5℃

винтовые чиллеры с водяным охлаждением

Циркуляционный насос MAX 2,3 м³/ч~12 м³/ч 2 бар

точность температуры ±0,5℃

промышленные водоохладители

Циркуляционный насос MAX 2,3 м³/ч~12 м³/ч 2 бар

точность температуры ±0,5℃

Модель LG2-75W LG2-100W LG2-140W LG2-180W LG2-230W LG2-280W
Диапазон температур  -25℃~5℃
Мощность охлаждения
-20℃
кВт 80 111 158 206 259 318
Ккал/час*10³ 68.8  95.5  135.9  177.2  222.7  273.5 
Мощность 3N/400V/50HZ
Cooling input power at (-20℃) 56 74  105  136  166  205
Компрессор Форма полузакрытый двухвинтовой компрессор
Диапазон регулирования тепла 25%~100%
Охлажденная вода Форма   Пластинчатый, сухой, переливной или падающий пленочный теплообменник
Объем охлажденной водыТ/Н 24 32  46  59  75  92 
Перепад давления воды 40~80
Размер соединения DN65 DN80 DN100 DN125
Охлаждающая вода Форма Горизонтальный трубчатый теплообменник
Объем охлаждающей водыТ/Н 26 35 50 65 80 99
Перепад давления воды 40~80
Размер соединения DN80 DN100 DN125 DN150

LARGE WATER CHILLER ‘S APPLICATIONS

Обычно он используется для охлаждения машин и шпинделей в процессе производства, контроля температуры различных лекарственных препаратов и процессов приготовления в фармацевтической отрасли, а также контроля температуры химических реакций, таких как химическая или лабораторная кристаллизация и синтез, а также для испытаний новых энергетических транспортных средств и полупроводников.

Глобальный сервис

Обслужил более 30 000 клиентов.
Экспортируется в более чем 20 стран.

Сертификационные патенты

Прошла сертификацию CE, SGS, ISO.

Послепродажное обслуживание

Обеспечьте комплексное техническое обучение.
Круглосуточные решения.

Профессиональная команда

Основана в 2010 году, имеет 15-летний опыт работы в отрасли.
20% сотрудников - это технические специалисты.

Контроль качества

Визуальный осмотр.
Тест на производительность.
Тест на электробезопасность.

Свяжитесь с нами сейчас, чтобы получить подробную информацию о винтовых чиллерах и ценах.

Диапазон температур
Consider the production temperature requirements first. Different applications (such as air conditioning and low-temperature projects) have different temperature needs.
Cooling Capacity and Single Unit Cooling Capacity
The cooling capacity directly affects the energy efficiency and operating economy. When designing a chiller system, multiple units should be arranged to ensure production continues even if one unit is down.
Energy Consumption
Consider both electrical and steam consumption, especially for large systems. The goal is to maximize energy efficiency by considering the combined use of electricity, heat, and cooling.
Environmental Protection
Focus on the noise level and the impact of the refrigerants on the environment. Avoid using refrigerants that damage the ozone layer or are harmful to the environment, ensuring that the system meets environmental standards.
If you have any doubts about choosing the right chiller, feel free to contact us. Our 24/7 customer service team is available to provide professional consultation and offer custom-designed solutions.

The air cooled screw compressor chiller is mainly composed of the screw compressor, expansion valve, condenser, evaporator, and other components.
Below is the translation of the specific parts and their functions:
Винтовой компрессор  
It is the power source of the air-cooled screw chiller system. Its main function is to extract the vapor from the evaporator in a timely manner, maintain low temperature and low pressure, and increase the pressure and temperature of the refrigerant vapor through compression, creating conditions for the heat transfer of the refrigerant vapor to the external environment.
Конденсатор  
The air-cooled screw chiller uses a finned condenser. The condenser is a heat exchange device that works by transferring the heat of the high-temperature, high-pressure vapor discharged from the compressor to the surrounding cooling medium.
Расширительный клапан  
Since the high-pressure, normal-temperature refrigerant liquid cannot be directly sent into the low-temperature, low-pressure evaporator, it needs to be depressurized and its temperature reduced. Therefore, the expansion valve is used to obtain low-temperature, low-pressure refrigerant, which is then sent to the evaporator to absorb heat and vaporize.
 Испаритель  
Similar to the condenser, the evaporator is also a heat exchange device. It evaporates the low-temperature, low-pressure refrigerant liquid into vapor, absorbs heat from the cooled medium, reduces the temperature of the cooled medium, and provides low-temperature chilled water to achieve cooling. The evaporator, like the condenser, must have a sufficiently large area to work effectively.

*
*