Поиск по всей станции

Reactor Temperature Control Units TCU


TCU reactor temperature control system is mainly composed of a heating module, a constant temperature module and a cooling module. These modules work together to meet the complex and changeable temperature requirements in the pharmaceutical process. In the processing and production of drugs, the temperature in the reactor changes with the reaction time. The TCU system can accurately control this change process to ensure that the drugs are subjected to process reactions such as sulfidation, nitration, hydrogenation, hydrocarbonization, polymerization, condensation, etc. under suitable temperature conditions, thereby ensuring the quality and stability of the drugs.

TCU MODELS

  • TCS series Distributed Temperature Control System"      /&gt;<figcaption><span>APPLICATIONS The automatic temperature control system of this project uses computer control technology, which can enable the process operation and parameters of pharmaceutical production to be scientifically, effectively and strictly mo…</span></figcaption></figure></a></div><div class= TCS series Distributed Temperature Control System

    APPLICATIONS The automatic temperature control system of this project uses computer control technology, which can enable the process operation and parameters of pharmaceutical production to be scientifically, effectively and strictly mo…

    MORE
  • SR & ZLF series TCU Reactor Cooling Heating System"      /&gt;<figcaption><span>APPLICATIONS TCU temperature control system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquid – the “primary system”) infrastructure to integrate into a single fluid system or secondary loop use…</span></figcaption></figure></a></div><div class= SR & ZLF series TCU Reactor Cooling Heating System

    APPLICATIONS TCU temperature control system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquid – the “primary system”) infrastructure to integrate into a single fluid system or secondary loop use…

    MORE

загрузка...

已经是到最后一篇内容了!

Модель ZLF-35N
ZLF-35NS
ZLF-35NH
ZLF-35NSH
ZLF-50N
ZLF-50NS
ZLF-50NH
ZLF-50NSH
ZLF-80N
ZLF-80NS
ZLF-80NH
ZLF-80NSH
ZLF-125N
ZLF-125NS
ZLF-125NH
ZLF-125NSH
ZLF-200N
ZLF-200NS
ZLF-200NH
ZLF-200NSH
SR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Temp range  -45℃~250℃ (the max Temp is determined by the heat and cold source supplied by the user)-40-135(The maximum temperature range can be operated by using glycol water formula solution)  -120℃~250℃ (the max. Temp is determined by the heat and cold source supplied by the user)-40~135(The maximum temperature range can be operated by using glycol water formula solution)
Площадь теплообменника 3.5㎡ 5㎡ 8㎡ 12.5㎡ 20㎡ 3.5㎡ 5㎡ 8㎡ 12.5㎡ 20㎡
Electric heatingfunction H 25 кВт 35 кВт 50 кВт 65 кВт 80kW 25 кВт 35 кВт 50 кВт 65 кВт 80kW
With ‘H’ has heating function
Temp accuracy ±1℃
Циркуляционный насос 150 л/мин 2,5 бар 200 л/мин 2,5 бар 400 л/мин 2,5 бар 500 л/мин 2,5 бар 750 л/мин 2,5 бар 200 л/мин 2,5 бар 250 л/мин 2,5 бар 400 л/мин 2,5 бар 500 л/мин 2,5 бар 750 л/мин 2,5 бар
Расширительный бак   100L 200L 280L 390L 500L

  • Mlaintainability: the system shall be of good maintainability with a long-term and stable supply of spare parts forcomputers and templates and various sensors and actuators to be used. After our company training, the enterprise canmaintain by itself.
  • Scalability: the system is an open system, providing standard TCPlP data communication interface protocol,interfacesoftware and application software interface, with good flexibility and scalability, to meet the requirements of increasingproduction scale for measurement and control ability.
  • Security: this system has the authority mechanism, realizes the multilevel authority management, divides five diferentlevels to the operation user, different levels of user operation authority is also diferent. The control system is a relativelyclosed network, and the system network and enterprise LAN or extemal network between the configuration of a firewallcan effectively prevent viruses and network attacks, for the system to operate to create a secure environment.
  • Improve the stability of batches: according to the technological reguirement of batch production, establish theappro priate production model and strengthen the management of batches.Through the production batch productionplan designation, produ cion plan distribution and tracking management module, the realization of phammaceuticalproduction batch management.
  • Ensure that the integrity of the production data: by applying the computer management system in conformity withthe GlP standard and automatic control svstem, reaize the production of fully automatic data acquisition and monitoringeficient, accurate and complete by the computer system of colle cting and analyzing data processing, are prone to avoidthe traditional manual recording of lagging production data, missing and error.
  • Improve traceability of production records: traceability is GMP pharmaceutical producion data, the FDA and othernecessary content of medical industry certification, application of the phammaceutical and pharma ceutical producionauto mation control system intelig ent manufacturing qualtly infomation management system software, the batch numbergoods name, ime, equipment, operators and other pharmaceulical pro duction data in real time, complete and accuraterecords, and implement reverse retrieval process of the production data, can restore all the production status, productionenables producers to analyse the causes of defects of the quality of the products, at the same ime through data tracefunction enables pro ducers to have a better understanding of actual production status, provide data basis for improvethe production.
  • Energy saving and environmental protection: the application of production process and infommation managementsystem to pharmaceutical production has a signifcant effect of energy saving, at the same time reduce the intemmediatelink of pharma ceutical production, eliminate the waste of products in the production flow link.

If you haven’t found a suitable model yet, please try contacting us for assistance.

WeChat ID 086 15152266993

Submit your request to us and we will contact you within 24 hours
*
*

Multi-channel

Channel 1Channel 2Channel 3

Voltage

50HZ single phase50HZ three phase60HZ single phase60HZ three phase*
Submitting….
Отправлено успешно!
Submission failed! Please try again later
Email error!
Ошибка телефона!

LNEYA’s industrial chiller/heater is sold globally. Singapore, Malaysia, Japan, South Korea, Qatar, Middle Eastern countries, various European countries, and the United States and other regions.