Серия UST
ПРИЛОЖЕНИЯ
Suitable for temperature control in more usage scenarios
Used with reactors, reactors, microchannels, distillation systems, etc., and also used for heating and cooling of other equipment. Widely used in pharmaceutical, chemical, biological, semiconductor, new materials and other industries
Характеристики товара
Параметры продукта
Модель | UST-5530 UST-5530W | UST-7530 UST-7530W | UST-A1030 UST-A1030W | UST-A1530 UST-A1530W | UST-A2530 UST-A2530W | UST-A3830 UST-A3830W | UST-A6030 UST-A6030W | UST-A9530 UST-A9530W | |
Temp range | RT+10℃~+300℃ | ||||||||
Система управления | ПИД с обратной связью + наш специальный расчет динамического управления, контроллер ПЛК | ||||||||
Режим управления | Process temp control and jacket temp control mode | ||||||||
Temp difference | Установка или контроль разницы температур между маслом в рубашке и сырьем | ||||||||
Редактор программ | 5 программ, каждая программа может редактировать 40 шагов | ||||||||
Communication protoco | Протокол MODBUS RTU, интерфейс RS485 | ||||||||
Material temp feedback | PT100 OR 4~20mA or communication(normal: PT100) | ||||||||
Обратная связь по температуре | The temp of three points: the inlet and outlet of equipment, reactor material temperature(external temp sensor) | ||||||||
Medium temp acccuracy | ±0.5℃ | ±1℃ | |||||||
Material temp accuracy | ±1℃ | ||||||||
Мощность нагрева кВт | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
Охлаждение емкость |
300 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 |
200 ℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 95 | |
100 ℃ | 4 | 5 | 7 | 12 | 20 | 30 | 48 | 76 | |
65 ℃ | 1.8 | 2.2 | 3 | 5 | 8.5 | 12 | 19 | 30 | |
Циркуляционный насос max L/min bar |
35 | 50 | 50 | 110 | 150 | 200 | 250 | 400 | |
2 | 2 | 2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | ||
Панель управления | 7-inch touch screen, show temp curve\EXCEL data output | ||||||||
Защита безопасности | Self-diagnosis function; freezer overload protection; high pressure switch, overload relay, thermal protection device, high temperature protection and temp fault protection |
||||||||
Закрытая циркуляция система |
The whole system is full closed circulation, there is no oil mist at high temp and no water vapor at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature |
||||||||
Connection siz | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Connection size(water port) | ZG3/4 | ZG3/4 | ZG3/4 | ZG1 | DN32 PN10 | DN40 PN10 | DN40 PN10 | DN50 PN10 | |
Размер см | 40*70*130 | 45*70*160 | 40*70*160 | 70*100*175 | 70*100*175 | 80*120*185 | 150*100*185 | 200*145*205 | |
Вес кг | 110 | 120 | 160 | 195 | 265 | 395 | 615 | 950 | |
Power MAX 380V 50HZ |
7 кВт | 9 кВт | 12 кВт | 17 кВт | 28 кВт | 41kW | 65 кВт | 96kW | |
Shell materia | Cold rolled sheet (REL7035) |
связаться с нами
Отправьте нам свой запрос, и мы свяжемся с вами в течение 24 часов