Поиск по всей станции

AES Series Thermal Stream Temperature Forcing System

AES Series Thermal Stream Temperature Forcing System

ПРИЛОЖЕНИЯ

AES series for Automatic test equipment in semiconductor, aerospace, military and other industries.

Such as ATE is used to measure the output signal of semiconductor devices,Used to evaluate the properties and performance of DUT, UUT, EUT to ensure use.

 

The output airflow cover of the testing machine will be covered bythe test product to form a test chamber with a relatively closedspace. The high or low temp airflow output by the testing machinewill cause the surface temp of the test product to change drastically,thus completing the corresponding high and low temp impact test.

It can isolate one lC or original component among many componentsand separately perform high and low tempimpact withoutaffecting other surrounding devices. Compared with the traditionalthermal shock test box, the temp impact rate is faster.

Compared to the traditional thermostat, there are several features:
Temperature range: -120 °C ~ +300 °C;
The temperature rise and fall is very fast, -55 °C ~ 150 °C < 10 seconds;
Temperature control accuracy: ±1 °C;
Temperature setting capability: ±0.1 °C;
Temperature display capability: ±0.1 °C;
Maximum air flow: 25m3/h;
Real-time monitoring of the real temperature of the IC under test to achieve closed-loop feedback and adjust the gas temperature in real time;
The temperature rise and fall time is controllable, programmable operation, manual operation and remote control.

 

Диапазон температур -40℃~225℃ -60℃~225℃ -80℃~225℃ -100℃~225℃ -120℃~225℃
Точность температуры ±0.1℃(Steady state outlet temperature)
Air requirements Air filter < 5um air oil content < 0.1um air temp and humidity:5℃-32℃ 0-50%RH
Air treatment capacity 10m³/h-m³/h  pressure 5bar-7.6bar
Метод дросселирования Электронный расширительный клапан
Контроллер PLC Controller
Отображение и запись The pressure of the refrigeration system is realized by a pointer pressure gauge, and the pressure
of the circulation system is detected by a pressure sensor and displayed on the touch screen.
Основные компоненты Danfoss drying filter, Casto solenoid valve, Danfoss pressure controller, EBM fan ( air-cooled ), Danfoss
/ Emerson oil separator, SMC filter, Emerson electronic expansion valve, Johnson pressure sensor
Компрессор Tecumseh,Dorin
High temp cooling Possess high-temperature 225℃ direct cooling technology to meet the target and quickly cool
down during high-temperature operation.
Process control The remote target temperature can be controlled by combining the self created model free self built
tree algorithm and cascade algorithm
Размер 540*690*1320 540*690*1320 540*690*1320 800*1200*1750 1000*1500*1850

 

ПРИЛОЖЕНИЯ

Узнать больше

Semiconductor packaging and testing temp control solution


Since our founding in 2006, we have served over 30,000 customers and hold several patents that demonstrate our innovation and reliability. Our chillers are selected for over 100 university laboratory projects worldwide and exported to over 20 countries. We ensure the highest quality through a rigorous 3-step quality control process: visual inspection, performance testing, and electrical safety testing. Our commitment to excellence is further backed by our 24/7 customer support commitment. In addition, we have agents in the United States, Canada, Australia, Russia, and South Korea, making us a global, trusted partner for your chiller needs. Choose lneya for quality and support for your project.
18+

Years of experience

30000+

Satisfied Customers

25000

m² Production Area

80+

Patented Technologies

*
*
Предоставление....
Отправлено успешно!
Отправка не удалась! Пожалуйста, повторите попытку позже
Ошибка электронной почты!
Ошибка телефона!