Π’Π΅ΡΠΌΠΎΡΡΠ°ΡΡ Ρ ΡΠ»ΡΡΡΠ°Π½ΠΈΠ·ΠΊΠΎΠΉ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠΎΠΉ Π²ΡΠ΅ ΡΠ°ΡΠ΅ ΠΈΡΠΏΠΎΠ»ΡΠ·ΡΡΡΡΡ Π² ΡΠ°ΡΠΌΠ°ΡΠ΅Π²ΡΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΈ Ρ ΠΈΠΌΠΈΡΠ΅ΡΠΊΠΎΠΉ ΠΏΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΠΎΡΡΠΈ. Π Π½Π°ΡΠ°Π»Π΅ Π½ΠΎΠ²ΠΎΠ³ΠΎ Π³ΠΎΠ΄Π° ΠΊΠ°ΠΆΠ΄ΡΠΉ ΠΎΠΏΠ΅ΡΠ°ΡΠΎΡ Π΄ΠΎΠ»ΠΆΠ΅Π½ ΠΎΠ±ΡΠ°ΡΠΈΡΡ Π²Π½ΠΈΠΌΠ°Π½ΠΈΠ΅ Π½Π° Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎΡΡΡ ΠΎΠΏΠ΅ΡΠ°ΡΠΈΠΉ, Π° ΡΠ°ΠΊΠΆΠ΅ Π±Π΅Π·ΠΎΠΏΠ°ΡΠ½ΠΎ ΠΈ ΡΡΡΠ΅ΠΊΡΠΈΠ²Π½ΠΎ ΡΠΊΡΠΏΠ»ΡΠ°ΡΠΈΡΠΎΠ²Π°ΡΡ ΡΠ»ΡΡΡΠ°Π½ΠΈΠ·ΠΊΠΎΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ½ΡΠ΅...
Check the machine for damage during installation of the ultra-low temperature bath. Choose a suitable place for installation and future maintenance. The installation site must be a floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. It should be placed in a machine room with a room temperature of 4.4-43.3 ° C. There should be enough space around and above the unit for routine maintenance work. At the end of the unit, a pipe space for cleaning the condenser tube bundle should be left, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate diameter of the ultra-low temperature constant temperature tank, the cooling system and the cold water system of the unit during high-power operation, and connect them correctly. For ordinary applications, the water flow speed through the evaporator and the condenser is allowed to be 1.0-3.6m/s. between. The water flow should be stable under any load conditions. All chilled water and cooling water piping should be designed and installed in accordance with conventional methods. The chilled water pump should be located on the inlet pipe of the unit to ensure positive pressure and flow within the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down.
The pipe should have a strong support independent of the cryostat group to prevent stress from being applied to the components of the cryostat group. The hangers are set up to facilitate pipe alignment. In order to reduce noise and vibration, it is better to install a vibration isolator on the pipeline. In order to use the ultra-low temperature thermostatic tank group cost-effectively, it is recommended that the water treatment expert analyze the water supply quality of the evaporator and the condenser. The bad water quality will cause the scale to affect the transmission. Heat, or corrosion deposits, breeding organic matter, affecting the performance of the unit, increasing operating and maintenance costs.
In general, proper water treatment and periodic cleaning of the tube bundles maintain their good performance. If existing water quality conditions cannot be improved by appropriate methods, then consideration should be given to allowing the bundle to have a large fouling factor or to specify a specific Structural materials, after the test leak is completed, all the nozzles must be rust-proof.
During the use of the ultra-low temperature bath, you need to understand the instruction manual to avoid safety accidents during operation.
ΠΠΎΡ
ΠΎΠΆΠΈΠ΅ ΡΠ΅ΠΊΠΎΠΌΠ΅Π½Π΄Π°ΡΠΈΠΈ
-
Reasons for the decrease of heat transfer effect of vertical ultra-low temperature refrigerator
1871If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 Β°C, resulting in low heat transfer efficiency...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
ΠΠΎΠ΄ΡΠΎΠ±Π½ΡΠ΅ ΡΠ²Π΅Π΄Π΅Π½ΠΈΡ ΠΎ ΡΠΈΠΏΠ°Ρ , ΡΡΠ½ΠΊΡΠΈΡΡ ΠΈ Ρ Π°ΡΠ°ΠΊΡΠ΅ΡΠΈΡΡΠΈΠΊΠ°Ρ ΠΏΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΡ ΠΎΡ Π»Π°Π΄ΠΈΡΠ΅Π»Π΅ΠΉ
1525When it comes to industrial chillers, everyone must know it, but what are the specific types? It is a kind of cooling equipment that can continuously perform the cooling function, which is also an important manifestation of the function of industr...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
Π’Π΅ΡΡ ΡΠ°Π±ΠΎΡΠ΅ΠΉ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΡ Π°ΠΊΠΊΡΠΌΡΠ»ΡΡΠΎΡΠ½ΠΎΠΉ Π±Π°ΡΠ°ΡΠ΅ΠΈ ΡΠ»Π΅ΠΊΡΡΠΎΠΌΠΎΠ±ΠΈΠ»Ρ
1619ΠΠΎΡΠΌΠ°Π»ΡΠ½ΡΠΉ ΡΠ°Π±ΠΎΡΠΈΠΉ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ½ΡΠΉ Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½ Π±Π°ΡΠ°ΡΠ΅ΠΉ Π΄Π»Ρ ΡΠ»Π΅ΠΊΡΡΠΎΠΌΠΎΠ±ΠΈΠ»Π΅ΠΉ ΡΠΎΡΡΠ°Π²Π»ΡΠ΅Ρ -30 ~ 52 Β°Π‘, Π° ΡΠ°Π±ΠΎΡΠΈΠΉ ΡΠ΅ΠΌΠΏΠ΅ΡΠ°ΡΡΡΠ½ΡΠΉ Π΄ΠΈΠ°ΠΏΠ°Π·ΠΎΠ½ -46 ~ 66 Β°Π‘, ΡΠ΅Π³ΠΎ ΡΡΡΠ΄Π½ΠΎ Π΄ΠΎΡΡΠΈΡΡ Ρ ΠΏΠΎΠΌΠΎΡΡΡ ΡΡΡΠ΅ΡΡΠ²ΡΡΡΠΈΡ Π±Π°ΡΠ°ΡΠ΅ΠΉ. Π₯ΠΎΡΡ Π»ΠΎΠΊΠ°Π»ΡΠ½ΡΠ΅ ΠΌΠ΅ΡΡ ΠΏΠΎ ΡΡΠ΅ΠΏΠ»Π΅Π½ΠΈΡ ΠΌΠΎΠ³ΡΡ Π±ΡΡΡ...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ -
Parameters of small gas condensing liquefaction system
1748During the process of loading and unloading gasoline and refueling vehicles, and collecting high-concentration gas from the chemical plant. One or two methods in the process of adsorption or condensation, or the conversion of oil and gas from a ga...
ΠΠΎΡΠΌΠΎΡΡΠ΅ΡΡ Π΄Π΅ΡΠ°Π»ΠΈ
LNEYA ΠΡΠΎΠΌΡΡΠ»Π΅Π½Π½ΡΠ΅ ΡΠΈΠ»Π»Π΅ΡΡ ΠΡΠΎΠΈΠ·Π²ΠΎΠ΄ΠΈΡΠ΅Π»Ρ ΠΠΎΡΡΠ°Π²ΡΠΈΠΊ