The importance of constant temperature equipment in oil bath heating systems
The constant temperature equipment of the oil bath heating system is used for dynamic temperature control of fluid cooling and heating with heat conducting medium, which is applied to high-precision industries such as pharmaceuticals, chemicals and semiconductors, and helps customers complete temperature control of the process. It is equipped with biochemical experimental equipment such as reactors, distillation, evaporators, and Rotary evaporator to control the cooling and heating of heat conducting medium or reaction materials.
The power switch of the transformer cooling system control box for the constant temperature equipment of the oil bath heating system adopts a dual power automatic switching device. Its main function is to automatically switch between the main and backup working power supplies. When a common power supply failure occurs, it automatically switches to the backup power supply. When both power supplies are normal, the common power supply is working and the backup power supply is in standby mode.
The programmable controller (PLC) is the control of the execution part of the air cooler control device, which receives various status signals from the transformer to control the execution part.? When the transformer of the oil bath heating constant temperature system is put into operation, the main cooler is put into operation, that is, the working group cooler is running. The auxiliary cooler is controlled based on the oil surface temperature, winding temperature, load signal, etc. of the transformer, and can be started as follows.
The power of the entire system of the constant temperature equipment in the oil bath heating system is provided by the compressor. The compressor is equivalent to moving a physical object from a low potential position to a high potential position. In the system, its purpose is to compress low-temperature gas into high-temperature gas through the compressor, and then the gas exchanges heat with other media in the heat exchanger. So the quality of the compressor will directly affect the refrigeration effect of the entire oil bath heating constant temperature system.
The function of the constant temperature equipment condenser in the oil bath heating system is to cool the high-temperature and high-pressure refrigerant superheated steam discharged by the compressor into a liquid or gas-liquid mixture. The heat released by the refrigerant in the condenser is carried away by the cooling medium (water or air), and the liquid low-temperature refrigerant is easily evaporated at low pressure, converted into steam, and absorbs the heat of the cooled medium to achieve refrigeration purposes.
Похожие рекомендации
-
Полупроводниковые испытания Двухканальный нагревательный циркуляционный прибор
1334Двухканальный нагревательный циклер для тестирования полупроводников относится к устройству, используемому для тестирования полупроводниковых приборов (например, силовых полупроводников), которое может одновременно управлять двумя независимыми каналами тестирования для выполнения нагрева и охлаждения...
Посмотреть детали -
Noise description of common faults in high and low temperature integrated equipment
1877High-low temperature integrated machine equipment may cause malfunction due to improper operation, then how to deal with noise failure of the equipment, and then analyze the noise too high. The suction of high and low temperature integrated equipm...
Посмотреть детали -
Производитель сверхнизкотемпературной заморозки анализирует причину засорения холодильной системы
2047With the continuous development of technology, ultra-low temperature refrigeration technology is also constantly developing, and manufacturers are also increasing. Of course, the technology of different manufacturers is different. Once the refrige...
Посмотреть детали -
How to avoid operational errors in fluid heat transfer temperature control systems?
1717During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes. 1. The operation of the fluid heat trans...
Посмотреть детали