Описание энергоэффективного высоко- и низкотемпературного циркуляционного бокса
With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.
The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.
Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.
These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Похожие рекомендации
-
Описание выбора типа и классификации криогенных охладителей мощностью 40 ГВт
1682Если разные предприятия и разные отрасли промышленности предъявляют разные требования к криогенным холодильникам Wuxi Guanya 40GW, то и выбор модели также отличается. Поэтому лучше иметь четкое представление о потребностях при выборе криог...
Посмотреть детали -
На что следует обратить внимание при хранении хладагента в чиллере? Каковы правила приемки
1547Хладагент - это вещество, необходимое для обеспечения холодильного эффекта в чиллере, которое представляет большую потенциальную опасность для безопасности в процессе использования. Хладагент, также называемый хладагентом, хладагентом-носителем и снежным семенем, используется в различном оборудовании...
Посмотреть детали -
Operation Precautions for ZLF/SR Series Reactor Temperature Control Equipment
1726The temperature control equipment of the reaction kettle adopts the PID control method, which greatly improves the temperature control accuracy of the whole machine. The microcomputer for cooling or heating will automatically switch to work accord...
Посмотреть детали -
Подробная инструкция по эксплуатации промышленного чиллера
2130Процедура установки водяного охладителя включает:1. Во время установки проверьте, не повреждена ли машина, и выберите подходящее место для установки и дальнейшего обслуживания. Место для установки агрегата должно быть напольным или...
Посмотреть детали