Cooling method for semiconductor testing chiller to meet temperature control requirements

Although there are many manufacturers of temperature control equipment in China, there are few self-developed semiconductor testing chillers. Especially in high-precision measurement and control, semiconductor testing chillers have developed a model that combines high accuracy, high stability, The high-power temperature control system with wide adjustment range is of great significance.
Cooling method of chiller for semiconductor testing
1. Direct cooling method: The cooling unit directly cools the circulating water. First, the temperature sensor collects the temperature value to the temperature controller, and then after a specific control algorithm, the temperature controller controls the cooling unit and the heating unit to perform cooling and heating processes, thereby controlling the temperature near the set value. When the circulating water temperature deviates from the set value, the control system first performs cooling or heating treatment. When the circulating water temperature enters the set threshold range, the circulating water temperature is gradually stabilized by fine-tuning the cooling and heating power.
The temperature control method directly controls the circulating water, the temperature control accuracy is high, and can be used under low temperature conditions; the disadvantage is that the system structure and the control program are complicated.
2. Indirect cooling method: Generally, it is a kind of temperature adjustment method to obtain the required water temperature by adjusting the flow rate ratio of the circulating water of two different temperatures. The mixing process is mainly achieved by adjusting the opening of the electric three-way valve. First, the temperature sensor separately detects the temperature of the two circulating water, and transmits the temperature value to the temperature controller, and then the temperature controller controls the opening of the electric three-way valve according to a specific control algorithm, that is, it controls two different temperatures of water The final mixing ratio is the final temperature of circulating water.
The chiller heat exchanger for semiconductor testing is a widely used indirect cooling device in modern industrial production. It can achieve heat transfer between two or more different temperature fluids, so that the temperature of the high temperature fluid or the low temperature fluid can meet the process requirements. . During the working process of the heat exchanger, different heat exchange power and heat exchange efficiency can be achieved by adjusting the flow rate of the medium or refrigerant. This kind of equipment has large heat exchange power, usually more than several hundred kilowatts, and is bulky, which is not easy to integrate and transport.
LNEYA semiconductor test chiller adopts advanced liquid temperature control technology, actively explores and studies component test system, mainly used for temperature test simulation in semiconductor test, with wide temperature orientation and high temperature rise and fall, temperature range is -92°C ~ 250°C, suitable for various testing requirements, solving the problem of temperature control lag in electronic components. The ultra-high temperature cooling technology can directly cool from 300°C.
Похожие рекомендации
-
Применение системы контроля температуры газового охлаждения в оптическом модуле
1566The gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devi...
Посмотреть детали -
Описание выбора насоса в блоке управления температурой системы с насыщенным паром
1670The steaming system temperature control unit is one of the more used equipment in the pharmaceutical chemical industry. The performance of the LNEYA steaming system temperature control unit depends on the design of the whole system and the specifi...
Посмотреть детали -
Glycol chiller installation requirements
1777In the summer, the use of glycol chillers is relatively frequent. Efficient glycol chillers are also needed. Therefore, when installing glycol chillers, they need to be installed on a smooth and tidy floor. Why choose a smooth ground when installi...
Посмотреть детали -
High and low temperature hot and cold water cooling machine for battery motor test
1654LNEYA high and low temperature cold and heat integrated water cooler is used in battery thermal management of new energy electric vehicles. The following is the relevant principle applied in thermal management.The high and low temperature cold and...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик