The safety of heat transfer oil in water-cooled chillers
In order to achieve better operating efficiency, water-cooled chillers need to choose branded heat transfer oil, but you need to pay attention to safe placement, a little carelessness will cause adverse effects.
Although the heat transfer oil of the water-cooled chiller has a higher boiling point, it is still a flammable liquid. Therefore, you should pay attention to safety when using it. Improper use may cause fire. The cause of the fire is caused by leakage. There are four main types of leakage and fire:
A. Fire in the heat preservation area.
Common misfire types in organic heat transfer oil systems. The heat transfer oil leaks at the instrument connection and penetrates into the heat preservation area. Then, in the presence of air, the circulating liquid and pipe heat will heat the heat conduction oil and gradually oxidize the liquid, causing the heat preservation area to be ignited and cause a fire.
B. Fire caused by pipeline leakage or burst.
The leakage or burst of the pipeline caused the heat transfer oil to flow into the hot gas flame zone and cause a fire.
C. The flash point causes a fire.
The factors that cause the flash point fire are higher than the low flash point temperature of the heat transfer oil, and there are heat transfer oil, air and fire sources at the same time.
D. Fire caused by process raw materials:
The main reason is that the heat-conducting oil leaks into the heating system, and its process raw materials are easily oxidized and have oxidizing substances, which causes a fire.
In addition to the above four types of fires, more attention should be paid to the use of gas-phase systems. If a large amount of heat transfer oil vapor leaks, aerosol mist may be formed. This mist may cause explosion and combustion in the air when exposed to an open flame.
Therefore, the heat transfer oil of water-cooled chillers is related to its operating efficiency and safety, so it is necessary to do a good job in the repair and maintenance of the hot oil system to prevent the leakage of the heat transfer oil.
Похожие рекомендации
-
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
1855The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
Посмотреть детали -
Применение систем отопления на мазуте в фармацевтической промышленности
1468Требования к температуре нагрева в фармацевтической промышленности очень разнообразны, поскольку различные фармацевтические процессы и этапы приготовления продуктов имеют разные температурные требования. Ниже приведены некоторые требования к температуре нагрева...
Посмотреть детали -
Solution to High and Low Pressure Fault of Water Cooled Chiller
2029The method to eliminate the shortcomings of high and low pressure of water-cooled chiller has always been a key point and difficulty in the industry, so it is very important to master the solutions to the shortcomings of high and low pressure of w...
Посмотреть детали -
Описание работы компрессора высоко- и низкотемпературной цикловой машины
1896Важность работы компрессоров машин с высоко- и низкотемпературным циклом должна быть известна каждому, поэтому компания LNEYA напоминает пользователям, что необходимо понимать здравый смысл работы компрессора. Высокотемпературный и низкотемпературный...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик