-80 °C производитель холодильника рабочие точки оборудования
Когда пользователь выбирает холодильник -80 °C, он, безусловно, должен иметь надежное качество. Холодильник Wuxi Guanya (LNEYA)-80 °C должен быть внимательным к деталям его работы во время эксплуатации, чтобы избежать поломки оборудования, вызванной воздействием...
The following items should be mastered during use. Please check if the -80 °C refrigerator is damaged during installation, and choose the right place for installation and future maintenance. The site where the unit is installed must be the floor, mounting mat or foundation with a level of 6.4 mm and can withstand the operating weight of the unit. – It should be placed in a machine room with a room temperature of 4.4-43.3 °C. There should be enough space around and above the unit for routine maintenance work. A pipe space for cleaning the condenser tube bundle should be left at one end of the device, or a door hole or other suitable hole can be used.
Select the water pipe of the appropriate pipe diameter, the cooling system and the cold water system of the -80 °C refrigerator unit during high power operation, and connect them correctly. For normal applications, the water flow rate through the evaporator and condenser is between 1.0 and 3.6 m/s.
Under any load, the water flow rate should be stable. All chilled water and cooling water pipes should be designed and installed according to the conventional method. The chilled water pump should be located on the inlet pipe of the unit to ensure the positive pressure and flow in the unit. The piping should be provided with a damping tube to ensure proper flexibility and to prevent the evaporator water from being drained when the pump is shut down. The piping should have a solid support independent of the -80 °C refrigeration unit to prevent stress from being applied to the refrigeration unit components. The hangers are set up to facilitate pipe alignment.
-80 °C refrigerator manufacturers will provide corresponding instructions when the equipment is shipped from the factory, users need to read and operate carefully when using.

Похожие рекомендации
-
Details of the temperature control system of the isolated reactor
1059The temperature control system of the isolated reactor adopts the heat-conducting medium to perform dynamic temperature control of fluid cooling and heating, and to control the cooling and heating of the heat-conducting medium or the reaction mate...
Посмотреть детали -
Structural Characteristics of Industrial Recirculating Chiller
878In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
Посмотреть детали -
На что следует обратить внимание при установке системы охлаждения сваи для зарядки постоянным током?
874Прежде чем устанавливать систему охлаждения свай постоянного тока, необходимо понять характеристики оборудования. Сюда входят такие характеристики, как размер, вес, диапазон рабочих температур и потребляемая мощность. Убедитесь, что оборудование...
Посмотреть детали -
Разработка температурного цикла охлаждения для испытаний полупроводников
1158Индустрия полупроводниковых микросхем IC в настоящее время является относительно новой отраслью в Китае. Поскольку требования индустрии микросхем становятся все выше и выше, сложность испытаний также постоянно возрастает. С этой целью компания LNEYA представила полупроводниковый...
Посмотреть детали