Знакомство с качеством и конфигурацией промышленных холодильных и нагревательных циркуляторов
С развитием и прогрессом общества промышленные холодильные и нагревательные циркуляторы находят все большее применение в промышленности, а технологический уровень становится все более сложным. Итак, на что следует обратить внимание пользователям после покупки...

1. In order to consume electricity, many companies will cut off the power after the experiment. According to the technical staff, we explained that if the industrial refrigeration and heating circulator is powered off in winter, the inner tank is prone to aging, thereby reducing the equipment’s performance. service life.
2. During normal use, when the temperature in the box drops to a certain set value, the thermostat will cut off the power by itself. At this time, the pressure of the refrigerant is already very low, and the compressor is relatively small compared to the load of the motor. , the motor is easy to start normally, if the power is forced to be cut off, the power will be turned on immediately when the refrigeration has a relatively high pressure. Although the high voltage will cause the motor to be overloaded, it is easy to burn the motor due to excessive current. Therefore, industrial refrigeration and heating circulators cannot be powered off at will.
3. The industrial refrigeration and heating circulator that is in a power-off state cannot be powered on at will, especially for newly purchased equipment, it must be placed for one to two hours before it can be powered on.
4. There is a certain space between the inner tank and the outer shell. The electric heating tube is used to provide heat to transfer the heat to the heat-conducting oil medium, and then the heat is transferred to the inner tank of the reactor through the heat-conducting oil bath, and the material medium in contact with the inner tank passes through the steel plate. The heat is used to increase the temperature, and the temperature required for the reaction of the material is slowly reached.
5. The electric heating tube is generally 220v/380v voltage, and the 220v electric heating tube must be three in a group, connected to form three power supply requirements (general industrial production does not use direct single-phase wiring), through three in a group, you can According to the total number of electric heating pipes required, multiple groups are formed.
There are certain differences in the quality and configuration of industrial refrigeration and heating circulators from different manufacturers. Users can judge and use them according to the reaction kettle heating and temperature control machine they purchased.
Похожие рекомендации
-
Циркулятор отопления закрытой холодильной установки Ежедневное руководство по обслуживанию
1365The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life. The user...
Посмотреть детали -
Benefits of Winterizing and Degassing Prior to Distillation
966Prior to distilling oil, you should follow a winterization and degassing procedure. The winterization will remove fats, waxes, and other inactive and unwanted compounds. Degassing will remove any solvents and other inactives with low boiling point...
Посмотреть детали -
Меры предосторожности при работе компрессора устройства холодильно-нагревательного цикла
1142Производительность компрессора в холодильно-отопительном цикле устройства очень важна. При выборе марки компрессора холодильно-отопительного циклового устройства LNEYA, компрессоры отечественных и зарубежных брендовых производителей специ...
Посмотреть детали -
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
1468When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
Посмотреть детали