Описание требований к холодильному маслу для установки рекуперации газов органических отходов
The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigeration oil is also important, then the refrigeration oil has What is the requirement?
The cloud point of the frozen oil of the organic waste gas recovery device refers to the temperature at which the paraffin is precipitated in the frozen oil and the lubricating oil becomes turbid when the temperature is lowered to a certain value. The cloud point of the refrigeration oil used in the device should be lower than the evaporation temperature of the refrigerant, otherwise it will cause the throttle valve to block or affect the heat transfer performance.
The temperature at which the frozen oil is cooled under experimental conditions to stop flowing is referred to as the freezing point. The freezing point of the frozen oil used in the organic waste gas recovery device should be as low as possible (such as R22 compressor, the refrigeration oil should be below -55 °C), otherwise it will affect the flow of the refrigerant and increase the flow resistance, resulting in poor heat transfer. as a result of.

An important parameter in the characteristics of the oil viscosity of the refrigerating oil. Different refrigerants should be used to select different refrigerating oils. If the viscosity of the frozen oil is too large, the mechanical friction power, friction heat and starting torque will increase. On the other hand, if the viscosity is too small, the desired oil film cannot be formed between the moving parts, so that the desired lubrication and cooling effect cannot be achieved.
The flash point of a frozen oil is the temperature at which the lubricating oil is heated to the point where it is ignited when it comes into contact with the flame. The flash point of the frozen oil used in the organic waste gas recovery device must be 15 to 30 ° C higher than the exhaust gas temperature to avoid burning and coking of the lubricating oil. Organic waste gas recovery devices such as chemical stability and oxidation resistance, moisture and mechanical impurities, and insulation properties.
As far as the current environmental protection trend is concerned, if the company has organic waste gas, it is recommended to buy an organic waste gas recovery device for gas treatment as soon as possible to avoid troubles.
Похожие рекомендации
-
Проверка двигателя компрессора чиллера вызывает износ
1094Качество моторного масла для чиллеров может быть одной из основных причин, влияющих на износ коленчатого вала. Если моторное масло используется в холодильной системе чиллера, то несоответствующее требованиям и некачественное моторное масло может стать причиной износа коленчатого...
Посмотреть детали -
Why does the glass reactor need a heating refrigeration circulator in use?
922The glass vacuum reactor is of double-layer glass design. The inner layer is filled with reaction solvent for stirring reaction, and the interlayer can be connected with different cold and heat sources (freezing liquid, hot water or hot oil) for c...
Посмотреть детали -
-
KRY series water chiller for new energy vehicle quality test
1038The new energy vehicle powertrain test bench can be directly connected to the power output end of the electric drive assembly through the half-shaft. The front end is equipped with high-precision torque sensor and speed sensor to provide high-pre...
Посмотреть детали