Operation and Maintenance of Small Water Chiller Units
2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides small water chiller units, welcome to buy!
Похожие рекомендации
-
The cooling circulation system is used to collect the non-condensable tail gas in the distillation s
1596Most rectification towers are two-stage condensation. The first stage uses cooling water, mainly condensing the top steam, and the second stage uses chilled water or ethylene glycol, which is mainly used to treat tail gas and remove a small amount...
Посмотреть детали -
Характеристики и преимущества чиллеров с воздушным охлаждением
16871. Конфигурация чиллера с воздушным охлаждениемВоздушные чиллеры можно разделить на вихревые чиллеры с воздушным охлаждением и винтовые чиллеры с воздушным охлаждением в зависимости от типа компрессора. Вихревой чиллер с воздушным охлаждением в основном состоит из вихревого компрессора, испарителя,...
Посмотреть детали -
-
Structural Characteristics of Industrial Recirculating Chiller
1323In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик










