Start-up work for new energy thermal management
In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, metal insulation hose temperature range -60 ~ 250 ° C; pressure ≤ 2.5 bar.
When the new energy thermal management configures the metal insulation hose and other pipelines carefully, when referring to its pressure and overpressure capability, caliber and temperature range, consider the lift pressure of the circulating pump inside the equipment. New energy thermal management should choose pipelines with good quality and sufficient volume such as seamless steel pipe as much as possible. The pipeline connection between new energy thermal management and controlled objects should be as short as possible to reduce bending. When the pressure of the new energy thermal management circulation pipeline is too large, the pipeline pressure is insufficient, the pipeline and the reactor will be cracked, and the high temperature and low temperature heat conduction medium may be sprayed, which may cause personnel injury, burns, frostbite and ignition. The possibility of flammable materials, etc.; the pollution caused by the loss of reactants, property damage, and even the possibility of poisoning. The connection of new energy thermal management pipelines should be sealed and firm, with measures such as anti-vibration, grounding, rust prevention and pressure keeping, which can effectively prevent cracks from leaking and corrosion of pipelines;
New energy thermal management The selection of thermal insulation materials should first consider the temperature range of new energy thermal management equipment. It is important to select flame retardant materials. The temperature range of thermal insulation materials should include the temperature range of this new energy thermal management equipment, and have a temperature greater than 30 °C. margin. When the user ignores this problem, there is a possibility of fire. The insulation material package should be sufficient, otherwise the equipment control will not achieve the expected effect.

Other components of the new energy thermal management pipeline include valve components, gaskets, pressure gauges, cooling towers, cooling water pumps, etc. In order to ensure the stable operation of new energy thermal management equipment, the temperature range, pressure range and use of these components should be fully considered. Environment, use media, power and other parameters.
The management of new energy thermal management equipment should be carefully read the corresponding instructions, and then detailed preparations should be made before the corresponding preparations.
Похожие рекомендации
-
5L glass reactor thermal oil heating system
7505L glass reactor is a common laboratory equipment used for various chemical reactions. In order to ensure that the reaction is carried out at the required temperature, it is usually necessary to equip it with a heating system. Thermal oil (a...
Посмотреть детали -
Инструкции по контролю температуры для реакторов из нержавеющей стали и стеклянных реакторов
1199Reactor is a kind of reaction equipment in industrial production. It generally needs to be refrigerated or heated. Whether the temperature is suitable or not directly affects its reaction effect. Therefore, if conditions permit, it is generally e...
Посмотреть детали -
Как выбрать охладитель и машину для литья под давлением?
1169A. Первый способ: охладитель 1HP с водяным охлаждением может быть оснащен 80-тонной машиной для литья под давлением, и температура может контролироваться на 5-10 градусов.Охладитель 1HP с водяным охлаждением может быть оснащен 100-тонной машиной для литья под давлением, и...
Посмотреть детали -
Небольшой переворот для борьбы с ледяным затором в высоко- и низкотемпературных жидкостных циркуляционных охладителях
838In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
Посмотреть детали