New energy vehicle testing comprehensive test box filled with heat transfer oil
In order to ensure the correct operation of the machine, the new energy vehicle inspection integrated test box must ensure that no air bubbles remain in the system, ensure that the heat transfer medium outlet is connected to the lower interface of the reactor, and the heat transfer medium inlet is connected to the upper interface of the reactor. When filling the heat-conducting medium, care must be taken to prevent the heat-conducting medium from overflowing to the upper cover and overflowing to the upper cover liquid, which may cause the thermal conductive medium to leak into the electrical equipment of the device, which may cause short circuit of the device, electrical failure, and control system failure; if the thermal medium is Flammable and explosive, may cause burning and explosion.
New energy vehicle testing integrated test box equipment power supply adopts three-phase four-wire system 380V 50HZ 60HZ 3 fire lines, one zero line, one ground line, the new energy vehicle test comprehensive test box must be grounded, the new energy vehicle test comprehensive test Power on the box and check if the continuity is correct (the continuous indicator lights up in green). If the continuity is not correct, please switch any two live lines until it is correct.
Before the thermal energy filling of the new energy vehicle testing comprehensive test box, the thermal fluid inlet of the new energy vehicle testing integrated test box is connected with the stainless steel bellows at the upper end of the reactor, and the heat transfer oil outlet of the new energy vehicle testing comprehensive test box is The heat transfer oil inlet at the lower end of the reactor is connected by a stainless steel bellows. Then open the exhaust valve directly above the new energy vehicle detection integrated test box equipment and open the filling port. New energy vehicle detection integrated test box heat injection into the filling port, turn on the power, press the dosing button (the system will automatically remove the air), 30 seconds apart, turn off the dosing button (continuously add thermal media during the process, Until the system exhaust valve hears the heat transfer medium back to the dosing tank). After filling the entire circulation system with the heat transfer medium, the expansion tank level index position is at the liquid level (when the system has basically eliminated the air), then close the exhaust valve, then turn off the dosing button and turn on the operation button. Set the temperature to 150 degrees and continue to vent. After reaching 150 degrees, run for about 5 minutes and reset the temperature to 25 degrees. After the target value is reached, it can be basically regarded as the system air.
The heat transfer oil of the new energy vehicle test comprehensive test box is not suitable for all heat transfer oils. It is recommended that users ask for the types of heat transfer oil suitable for the new energy vehicle test comprehensive test box, and then select the heat transfer oil.
Похожие рекомендации
-
Как устранить неисправность регулятора давления в холодильнике с ультранизкой температурой?
2003Если во время работы промышленного сверхнизкотемпературного холодильника произойдет сбой, связанный с контроллером, и если его вовремя не устранить, контроллер давления может выйти из строя. Контроллер давления играет очень важную роль в у...
Посмотреть детали -
Commissioning of circulating water chiller equipment for chemical enterprises
1682After completing the installation of circulating water chillers in chemical enterprises, certain debugging needs to be carried out for industrial chemical circulating water chillers in the early stage of operation. Only through careful debug...
Посмотреть детали -
Maintenance knowledge of 12HP (8.9kW) low temperature chiller
1853The user can arrange the operator to learn about the daily maintenance knowledge of the 12HP (8.9kW) low temperature chiller after purchase. It can not only improve the company's product quality, improve production efficiency, but also extend the ...
Посмотреть детали -
Description of the principle and mode of industrial water chiller refrigeration cycle
2139Anyone who knows about industrial waterchillers should know that it uses compressors to achieve the cooling effect.So, how does it work when refrigerating?1. Vapor compression refrigeration cycle.After cooling and pressurizing the vaporfrom the...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик










