Measures for stable operation of short-range molecular distiller
If the short-range molecular distiller is inefficient during operation, it will affect the use of the associated refrigeration heating temperature control system. How does the short-range molecular distiller maintain stable operation?
If the steam pressure entering the first effect film evaporator is too low, the preheating section of the liquid entering the tube will increase, which correspondingly shortens the film evaporation distance of the annular flow section, which will result in insufficient heat transfer and decrease in productivity. Or the discharge concentration does not meet the requirements. Therefore, within a certain range, appropriately increasing the pressure of the heating steam increases the temperature difference between the steam and the material, that is, the amount of heat transfer increases, and increases the evaporation rate. However, the vapor pressure should not be too high, otherwise the “dry wall area” of the heating pipe will reduce the heat transfer coefficient value, and the discharge concentration will be too high, which will easily cause the discharge pipe to clog and affect normal production.
The higher the vacuum of the short-range molecular distiller evaporating evaporator, the lower the boiling point of the liquid, and the higher the average temperature difference between the hot and cold fluids, the better the heat transfer effect. At the same time, under vacuum, the superheat temperature of the bubble generated at the lower inlet exceeds the temperature difference from the heat transfer in the film, so evaporation can be carried out completely on the surface of the film.
The short-flow molecular distiller is introduced into the rising film evaporator and the raw steam enters the first effect tube bundle and is discharged from the lower portion of the evaporator. In actual operation, the raw steam cannot be fully utilized, and a large amount of hot steam is discharged out of the evaporator together with the condensed water. The waste heat from the steam passing through the shell is used as a heat source, and a preheater is added before the feed liquid enters the effect-lift membrane evaporator to preheat the liquid to a higher temperature, so that not only the heat source can be fully utilized, but also waste is avoided. It can reduce the evaporator load and shorten the evaporation time, which is beneficial to the improvement of the evaporator production capacity.
The short-range molecular distiller should pay attention to maintaining its stable and efficient operation mode in actual operation, so that it is more stable and efficient in operation with the refrigeration heating temperature control system of LNEYA.
(This article is from the source network, if there is any infringement, please contact to delete.)
Похожие рекомендации
-
Описание давления в лабораторном специализированном охладителе
1574Лабораторный охладитель - одно из самых популярных устройств в отрасли механического оборудования. По этой причине были специально собраны соответствующие инструкции по давлению, чтобы помочь вам лучше понять лабораторный чил...
Посмотреть детали -
Применение системы контроля температуры газового охлаждения в оптическом модуле
1566The gas cooling temperature control system has a wide range of temperatures and can be widely used to meet the requirements of more production and engineering environments. It is applicable to reliability tests such as chip, microelectronic devi...
Посмотреть детали -
Инструкции по эксплуатации лабораторного холодильного отопительного цикла
1586Благодаря широкому применению в фармацевтической и химической промышленности, лабораторный температурный холодильный нагревательный цикл занимает определенное место в фармацевтической химической промышленности в качестве вспомогательного общего оборудования для контроля температуры.
Посмотреть детали -
Equipment attention points of laboratory high and low temperature cycle equipment manufacturers
1697In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик