Каково техническое обслуживание гликолевых охладителей при ежедневной эксплуатации?
При ежедневной эксплуатации гликолевого охладителя, если не проводить техническое обслуживание, эффект охлаждения будет снижен. Поэтому для повышения эффективности работы мы рекомендуем проводить необходимое ежедневное обслуживание. Холодильн...
Refrigeration system inspection: Generally, after long-term use of ethylene glycol chillers, various problems will inevitably occur. In the event of a failure, the use of each part of the machine should be carefully checked, focusing on the refrigeration system, electrical system, air system and water system to determine whether their functions are normal. We usually examine them by sound and appearance. If there is a problem, it is recommended to replace it in time.
Refrigerant inspection: Regularly check whether the refrigerant of the glycol chiller leaks: It can be determined by referring to the parameters displayed by the high and low pressure meter on the front panel of the main unit. According to the temperature change of the air temperature (winter and summer), the pressure display of the glycol chiller is also different. When the low temperature chiller is working normally, the high pressure shows 11-17kg, and the low pressure shows 3-5kg.
Cooling water system inspection: It is normal to check whether the cooling water system of the ethylene glycol chiller is normal, whether the cooling water tower fan and water spray shaft are in good operation, and whether the water supply in the built-in water tank of the chiller is normal.
System cleaning: Glycol chillers should be cleaned annually after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good cooling effect.
Voltage and current inspection: Regularly check whether the voltage and current of the glycol chiller are stable and whether the compressor is running normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
The above aspects are some of the areas that require routine maintenance. Of course, there are many other details that need your attention.
Похожие рекомендации
-
Vocs газоконденсатное очистное оборудование инструкции по обслуживанию компрессора
1551The vocs gas condensing treatment equipment is an important equipment in the process of exhaust gas treatment. Among them, the compressor is one of the main components, and its performance is affecting the operating efficiency of the entire vocs g...
Посмотреть детали -
Liquid Cooled Battery Pack BMS Test Cooling Water Circulator
1947As the temperature gradually increases, the use of the cooling water circulator for the BMS test of the liquid-cooled battery pack also gradually peaks. The rated power of the cooling water circulator for BMS testing of liquid-cooled battery packs...
Посмотреть детали -
Низкотемпературные охладители
1616Низкотемпературный чиллер стал очень важным промышленным холодильным оборудованием в последние годы. Он широко используется в промышленной сфере. Многие промышленные производства должны полагаться на него для достижения идеальных условий охлаждения. Таким образом, для ло...
Посмотреть детали -
Что делать при срабатывании сигнализации высокого давления в холодильнике
2064Люди должны обращать внимание на обслуживание крупномасштабного оборудования для контроля температуры, такого как промышленный охладитель воды. Иногда нормально столкнуться с аварийным сигналом высокого давления. Сначала необходимо выяснить причины высокого давления в промышленном...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик