Описание важности работы оборудования низкотемпературного цикла
Использование оборудования низкотемпературного цикла неотделимо от его стандартной эксплуатации. Оборудование низкотемпературного цикла LNEYA поставляется с соответствующим руководством по эксплуатации, и пользователи могут заранее знать, как его использовать. Низкотемпературный...
The low temperature circulation equipment, also known as the low temperature constant temperature bath, is a high precision constant temperature source with its own refrigeration, and has the function of a small chiller. Widely used in petroleum, chemical, metallurgy, pharmaceutical, biochemical, physical properties, testing and chemical analysis and other research departments, institutions of higher learning, factory laboratories and metrological quality inspection departments. According to the different opening size of the low-temperature cycle equipment, the constant temperature experiment can be carried out in the equipment, or it can be connected with other equipment through the hose and used together with the constant temperature source.
Low temperature cycle equipment should be used when the medium is used. When the working temperature of the medium in the equipment is relatively low, an aqueous solution of ethylene glycol or absolute ethanol is generally used. When the working temperature is 5 ° C to 80 ° C, deionized water is generally used. When the operating temperature of the low temperature cycle equipment is 80 ° C to 98 ° C, a 15% glycerin aqueous solution is generally used.
Low-temperature cycle equipment uses working power: 220V/50Hz, the power supply should be greater than the total power of the instrument, the power supply must have a good “grounding” device, use liquid medium in the low-temperature cycle equipment, the liquid level of the medium should be lower than the working table 30mm, Otherwise, the heater will be damaged when the power is turned on. When the temperature is higher than room temperature, please turn off the cooling, and the temperature inside the device can be completely controlled. Do not use ethanol when the temperature of the low-temperature cycle equipment is higher than 30 °C, so as to avoid danger. (Because of the high rate of volatilization at high temperatures, it is prone to danger).
The low-temperature circulation equipment should be placed in a dry and ventilated place, and there is no obstacle in the 300mm around the instrument. When the working temperature of the equipment is high, care should be taken not to open the upper cover, and do not enter the tank to prevent burns. After use, all the switches are turned off, the power is cut off; the cleaning work is done, and the work surface and the operation panel are kept clean.
Different manufacturers may have slightly different differences, so users need to know about the low-temperature cycle equipment they purchased. If you are not sure, you can contact the relevant manufacturers to obtain relevant information.
Похожие рекомендации
-
With these points, the use efficiency of the ultra-low temperature chiller can be more efficient
1682The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
Посмотреть детали -
Температурный контроль качества и надежности полупроводниковых пластин интегральных схем/чипов
2026Самая основная часть создания микросхемы - это дизайн-лента-упаковка-тестирование. Структура себестоимости микросхемы обычно состоит из 20% трудозатрат, 40% ленты, 35% упаковки и 5% тестирования. Тест на самом деле является наиболее во всех аспектах чипа. "Дешевый" шаг, но...
Посмотреть детали -
Что нужно учитывать при покупке системы охлаждения двигателя с масляным охлаждением?
1643Purchasing objects is nothing more than based on several types of methods: inquire with people around you, search and consult on the Internet by yourself, so that you can avoid some detours. 1. Parameter requirements: Ordering from the Internet is...
Посмотреть детали -
Влияние испарителя на холодильную систему в специальном приборе для низкотемпературного эксперимента
1865Специальный прибор для низкотемпературных экспериментов - это холодильно-нагревательное оборудование LNEYA для лаборатории. Важность испарителя очевидна. Так какое же влияние оказывает испаритель на холодильную систему? Согласно ди...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик