Semiconductor production process and testing process temperature control equipment
Use fluid fluorinated liquid for temperature control (minimum -100 degrees)
Gas cold and hot rapid temperature change thermal chuck
Low temperature gas cooler -120 degrees
Direct cooling cooling unit (-150 degrees)
The heating method within 40°C is heated by compressor hot air.
The Chiller ring system adopts a fully enclosed design and a magnetic drive pump.
Chiller100% helium detection, 100% safety inspection, to ensure safety and reliability.
chiller100% after 24 hours of continuous operation copy machine.

Конденсатор: micro-channel heat exchanger (air-cooled) plate heat exchanger (water-cooled)
Испаритель: Plate heat exchanger Throttling device: Electronic expansion valve Circulation system: The whole system is a fully closed system, low temperature does not absorb moisture in the air, does not volatilize heat transfer medium, low temperature automatically replenishes heat transfer medium into the circulation system.
Shell material: cold-rolled plate spray RAL7035
Inside the pipeline: including stainless steel SUS304, copper, ceramics, broken silicon, silicone sealant, PTFE
Control system: PLC programmable controller
Communication protocol: RS485 interface Modbus RTU protocol
Интерфейс Ethernet Протокол TCP/IP
Operation interface: LNEYA customized 7-inch color touch factory temperature curve display\EXCEL data export
Насос с переменной частотой позволяет регулировать циркуляционное гидравлическое давление и расход
The output pressure and flow rate of circulating fluid can be set on the operation panel. Even under various customer piping conditions, without bypass piping adjustment, the output pressure can be automatically controlled at the set output pressure through the frequency conversion pump. Thereby, the power consumption of a pump can be reduced. Depending on the flow rate, bypass piping may be required
Circulation heating is possible without a heater because it is heated by the exhausted heat
Похожие рекомендации
-
Liquid Cooled Battery Pack BMS Test Cooling Water Circulator
1944As the temperature gradually increases, the use of the cooling water circulator for the BMS test of the liquid-cooled battery pack also gradually peaks. The rated power of the cooling water circulator for BMS testing of liquid-cooled battery packs...
Посмотреть детали -
Описание эксплуатационных характеристик полностью закрытой холодильной и тепловой машины
2152В нефтяной, химической и фармацевтической промышленности полностью закрытые холодильные и нагревательные интегрированные машины необходимы многим предприятиям. Однако, делая выбор, пользователи должны понимать их эксплуатационные характеристики...
Посмотреть детали -
Метод отключения в случае отказа высокоточного высокотемпературного циркулятора
1855Высокоточный высокотемпературный циркулятор является одним из видов оборудования, используемого в фармацевтической и химической промышленности для поддержки различных реакторов. Если во время эксплуатации произойдет аварийное отключение электроэнергии, пользователям следует обратить внимание на оперативн...
Посмотреть детали -
Описание работы компрессора высоко- и низкотемпературной цикловой машины
1892Важность работы компрессоров машин с высоко- и низкотемпературным циклом должна быть известна каждому, поэтому компания LNEYA напоминает пользователям, что необходимо понимать здравый смысл работы компрессора. Высокотемпературный и низкотемпературный...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик