Как выбрать охладитель и машину для литья под давлением?
A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
We are a top chiller manufacturer. Welcome to buy our products.
Похожие рекомендации
-
Обмен знаниями по очистке трубопроводов мощных чиллеров
1407Многие компании из-за слабой осведомленности о ежедневном обслуживании мощных чиллеров долгое время не проводили эффективного технического обслуживания промышленных мощных чиллеров. Если промышленные мощные чиллеры не получают необходимого технического обслуживания, ...
Посмотреть детали -
Устранение основных неисправностей высоко- и низкотемпературной системы охлаждения
1907When the industrial high and low temperature cooling system is in use, what is the general reason if the temperature cannot drop down? How should we deal with such failures? Let's first analyze the principles and methods of industrial cooling. The...
Посмотреть детали -
Memory chip test equipment system program description
1764With the rapid development of the component industry, the memory chip test equipment has also made great progress. So, how much do users know about the memory chip test equipment? In order to simplify the test steps, reduce the complexity of the t...
Посмотреть детали -
Инструкции по обслуживанию приборов, связанных с высокой и низкой температурой
1667Жидкая среда должна быть добавлена перед использованием высоко- и низкотемпературного циркуляционного устройства. Жидкая среда обычно использует более 95% спирта, и жидкая среда не может быть ниже, чем рабочая пластина 20 мм. Высокая и низкая температу...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик