Какое влияние оказывает маслоотделитель на оборудование, анализирует производитель чиллеров
Oil separators use more accessories in the
chiller refrigeration system. So as users, we need to understand where the main
impact is in order to better use the equipment.
In the configuration of the chiller, the
position of the oil separator is after the compressor discharge port. After the
compressor, this arrangement is because the refrigerant is mixed with the
refrigerated lubricating oil only after compression in the compressor
compression chamber, and the oil separation operation is required after being
discharged from the compressor. Oil separation is the separation of
refrigerated lubricating oil.
Therefore, the role of the oil separator is
also quite large. Once the chiller manufacturer does not have an oil separator,
it will cause the refrigerated lubricating oil and refrigerant to enter the
condenser together, and the condenser will not work, and the condensation
effect will not be achieved.
The chiller manufacturer tells everyone
that the oil separator has a great effect on the separation of the mixture of
refrigerant and oil, which greatly affects the work of the chiller. If the
separation effect is good, the cooling effect of the entire chiller will be
very good. If the separation effect is poor, the refrigeration effect of the
entire refrigerator will also become poor. This is because once the refrigerant
and lubricating oil cannot be completely separated, a small part of the
lubricating oil will enter the condenser with the refrigerant, resulting in
defects The cooling effect.
Therefore, the existence of the oil
separator still has its effect. Once there is no oil separator, the lubricating
oil will not be recovered, precipitated, cooled and continue to be supplied to
the compressor, and the compressor will lose lubrication, thereby increasing
the gap between the components. Wear and tear improves the heat dissipation and
prevents the compressor from operating normally in a short period of time.
Of course, these chiller manufacturers have
already considered it, so all the parts that should be configured for the
chiller have already been configured.
Похожие рекомендации
-
Description of power consumption in LNEYA large refrigeration unit
1279In the process of operation, the cooling capacity and working conditions will affect the power consumption of the entire large refrigeration unit, but in order to avoid unnecessary power consumption, we need to understand the other power consumpti...
Посмотреть детали -
-
Описание диапазона применения системы температурных испытаний полупроводников
1486Система температурного тестирования полупроводников - это новое устройство компании LNEYA для тестирования полупроводниковых чипов. Так в каком диапазоне применяется система температурного тестирования полупроводников? Пользователям необходимо понимать конкретный диапазон применения, чтобы выбрать подходящую с...
Посмотреть детали -
Другое название взрывозащищенного холодильника: металлическая монтажная коробка для обработки холода
1123Взрывозащищенный холодильник Wuxi Guanya LNEYA использует одномашинную технологию самостоятельного складывания криогенной обработки. Он изготовлен из проволочной пластины из нержавеющей стали SUS304 с отдельной низкотемпературной коробкой, горизонтальной низкотемпературной коробкой, внутренним и внешним б...
Посмотреть детали