Применение промышленного чиллера с воздушным охлаждением в химической промышленности
Industrial air-cooled chillers are applicable to glass reactors, metal reactors and bioreactors for temperature control. In the field of chemistry and pharmacy, air-cooled chillers usually carry out necessary temperature control together with the chemical reaction of the material itself. Through the temperature change of circulating medium in sheath or coil, the temperature control of materials and the target process temperature of materials can be realized.
For the temperature control of stroke water cooler in pharmaceutical industry, the requirements for selecting temperature control equipment are relatively high. Compared with the common temperature range of – 60 ℃ – 100 ℃, a wider working temperature range is required. At the same time, different chemical reactions require different temperature curves, and the high-temperature and low-temperature integrated units need to work at any different temperature point within this temperature range.
The high and low temperature integrated device for temperature control of air-cooled chiller adopts electric heating, which can quickly increase the temperature of circulating medium. It adopts energy-saving design to realize the regulation of refrigeration capacity, accurately control the temperature of materials, realize the endothermic or rapid response to exothermic of materials, and meet the drug production needs of most industrial occasions.
The characteristics of explosion-proof air-cooled chiller are as follows:
(1) The cascade compression refrigeration cycle of the refrigeration unit can reach a lower temperature. Electric heating can quickly increase the temperature of the circulating medium.
(2) The adjustment of refrigerating capacity change is realized. The refrigerant flow is mainly controlled by PID, and the material temperature is accurately controlled. The traditional method is to use electric heating to offset the cooling of the compressor, which wastes energy.
(3) The combined control of heating and cooling realizes the rapid response to the heat absorbed or released by the material.
(4) The control of material temperature is mainly realized by refrigerant flow control. The refrigerant proportional control valve adopts the valve body of electronic expansion valve. Higher temperature control accuracy can be achieved.
The temperature control of air-cooled chiller consists of refrigeration cycle system, heating cycle system and automatic control system. For areas where the equipment has explosion-proof requirements, the positive pressure explosion-proof cabinet can be customized, which not only meets the explosion-proof requirements, but also reduces the number of explosion-proof parts and reduces the production cost of the whole machine.
Похожие рекомендации
-
Меры предосторожности для системы охлаждения чиллера при испытании на работу при низкой температуре
1966Существуют определенные различия в методах использования, функциях, структуре и т.д. различных типов систем охлаждения чиллеров для низкотемпературных эксплуатационных испытаний. Для промышленного низкотемпературного испытания чиллера требуется генерация тепла...
Посмотреть детали -
Attention points for the use of laboratory chiller manufacturers’ equipment
1430In the laboratory, a wide range ofexperimental instruments are widely used. When the experimental instruments arein operation, they are inseparable from the high-low temperature circulatingdevice refrigeration heating equipment. What should be ...
Посмотреть детали -
Model and size selection of cooling and heating circulator (pilot plant temperature control system)
1704The cooling and heating circulator adopts mechanical refrigeration, the low-temperature heating tube heats the high temperature, and the canned pump is used as the circulating pump. The liquid circulation of the whole system is closed and consists...
Посмотреть детали -
Влияние температуры на реакции химического органического синтеза
1973Органический синтез - распространенное химическое явление в химии. Температура оказывает на него важное влияние в течение всего процесса синтеза. При повышении температуры реакция поглощения тепла ускоряется, что приводит к значительному изменению...
Посмотреть детали
LNEYA Промышленные чиллеры Производитель Поставщик










