Industrial heating systems

  • The temperature control accuracy is around 0.5℃.
  • Employ a fuzzy PID adaptive controller
  • The temperature of the heat-conducting medium is fed back through the Pt100 sensor.
  • High-temperature cooling process, continuous heating and cooling can be achieved.
  • A fully enclosed system is equipped with an expansion vessel, which is insulated and does not participate in the liquid circulation.

Lneya’s UC/LY series is an economic type of heating circulators. UC/LY series utilizes industrial heating system. Its maximum cooling capacity is 130kW(UC-A13030N). There are options for air cooling and water cooling available. Lneya’s UC-XX30 series temperature range is +50℃~+300℃, and LY/UC-50XX series temperature range is +50℃~+170℃. UC series can only control the temperature of the heat transfer medium.

Industrial heating systems

50°C

Самый низкий

300°C

Самый высокий

±0.5°C

Точность контроля температуры


Модель UC-5530N UC-7530N UC-A1030N UC-A1530N UC-A2530N UC-A3830N UC-A6030N UC-A9530N UC-A13030N
Temp  range 50℃~300℃
Temp control Контроль температуры теплоносителя на выходе
Мощность нагрева кВт 5,5 кВт 7,5 кВт 10 кВт 15 кВт 25 кВт 38 кВт 60 кВт 95kW 130 кВт
Охлаждение
Вместимость
кВт при
300℃ 5,5 кВт 7,5 кВт 10 кВт 15 кВт 25 кВт 38 кВт 60 кВт 95kW 130 кВт
200℃ 5..5kW 7,5 кВт 10 кВт 13 кВт 25 кВт 38 кВт 60 кВт 95kW 130 кВт
100℃ 4 кВт 5 кВт 7 кВт 12 кВт 20 кВт 30 кВт 48 кВт 76kW 100 кВт
65℃ 1,8 кВт 2,2 кВт 3 кВт 5 кВт 8,5 кВт 12 кВт 19 кВт 30 кВт 40 кВт
Criculation pump
flow
Max35L/min 1.2BAR Max50L/min 1.2BAR Max50L/min 1.2BAR Max110L/min 1.5BAR Max150L/min 1.5BAR Max200L/min 1.5BAR Max250L/min 2.5BAR Max400L/min 2.5BAR Max400L/min 2.5BAR
Размер см 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205 200*145*205
Максимальная мощность
AC 380V 50HZ
7 кВт 9 кВт 12 кВт 17 кВт 28 кВт 41kW 65 кВт 101 кВт 136 кВт
Дополнительно 220V 60HZ three phase,440V~460V 80HZ three phase

Heat apparatus: provide a heat source and convert electrical energy into thermal energy, and heat the heat-conducting medium.


Circulating Pump: the driving heat-conducting medium circulates within the system to ensure that the heat is uniformly transferred to the target equipment (such as reaction vessels, microchannel reactors, etc.). The circulating pump is resistant to high temperature and corrosion, and its flow rate can be adjusted.

Our standard machine will not alarm. If you have any requirements, we can provide optional configurations.

ProblemsPossible CausesSolutions
Large temperature fluctuationPt100 sensor failureCalibrate or replace the sensor
Abnormal circulation pumpPipe blockage/voltage instabilityClean the pipes or check the power supply
High temperature alarmInsufficient cooling/overload of heaterCheck the cooling water flow or reduce the load

*
*