Добавьте нашего менеджера по работе с клиентами с помощью QR-кода ниже

WeChat/телефон
86 18914253067

+86 18914253067

Адрес электронной почты
market@lneya.com
Поиск по всей станции
With an extremely wide temperature range (-90℃~250℃) and precise temperature control capability (±0.5℃), it is equipped with a user-friendly color touch screen to give you a better thermal management experience.
Source chiller manufacturer, full range supports OEM.





| SUNDI- | 955W | 975W | 9A10W | 9A15W | 9A25W | 9A38W | 9A60W | 9A80W | |
| Диапазон температур | -90℃~+250℃ | ||||||||
| Точность средней температуры | ±0.5℃ | ||||||||
| Точность температуры материала | ±1℃ | ||||||||
| Мощность нагрева | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
| Мощность охлаждения | 250℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 |
| 0℃ | 5.5 | 7.5 | 10 | 15 | 25 | 38 | 60 | 80 | |
| -60℃ | 2.8 | 3.2 | 4.2 | 6 | 10 | 16 | 24 | 32 | |
| -80℃ | 0.8 | 1.2 | 1.6 | 2.1 | 3.5 | 6 | 11 | 15 | |
| -85℃ | 0.5 | 0.7 | 0.85 | 1.3 | 1.9 | 3.5 | 6 | 8 | |
| Flow、pressure max Л/мин бар |
35 | 50 | 60 | 110 | 150 | 250 | 400 | 400 | |
| 1.2 | 1.2 | 1.5 | 1.5 | 1.5 | 1.5 | 2.5 | 2.5 | ||
| Охлаждающая вода @20℃ |
3400L/H 1.5bar~4bar ZG1 |
4500L/H 1.5bar~4bar ZG1 |
5200L/H 1.5bar~4bar ZG1 1/4 |
8m³/H 1.5bar~4bar DN40 |
12m³/H 1.5bar~4bar DN50 |
20m³/H 1.5bar~4bar DN65 |
30m³/H 1.5bar~4bar DN80 |
40m³/H 1.5bar~4bar DN100 |
|
| Питание 380V 50HZ | 16 кВт | 27 кВт | 30 кВт | 42 кВт | 59kW | 83kW | 130 кВт | 188kW | |
Энергосбережение Комбинированный чиллер-обогреватель SUNDI-90℃~250℃ может автоматически регулировать подачу воды в соответствии с фактической потребностью в охлаждении, чтобы уменьшить расход охлаждающей воды. Модели с регулируемой частотой вращения помогают эффективно снизить эксплуатационные расходы. Охрана окружающей среды Компания LNEYA всегда активно выполняет свои экологические обязанности. Чиллер-обогреватель SUNDI-90℃~250℃ использует экологически чистые хладагенты, не разрушающие озоновый слой. Снижение выбросов углерода помогает вашей компании уменьшить углеродный след. Чиллер работает с очень низким уровнем шума, создавая более комфортную рабочую среду.


Pharmaceutical chemical industry
Different chemical reactions need to be carried out at different temperatures. In order to ensure the stability and safety of the reaction process, it is necessary to rely on the chiller heater combo to accurately control the temperature.
Biological production
Take cell culture in biotechnology as an example. Different cultivation stages require different temperatures. Whether it is high temperature or low temperature, SUNDI-90℃~250℃ chiller heater can be quickly adjusted through cooling and heating functions.
Semiconductor industry
In order to ensure the yield rate and extend the service life of semiconductor equipment, semiconductor companies often use chillers to control the temperature environment. Whether it is wafer manufacturing, ion implantation, etching, cleaning, packaging or testing, the support of chillers is indispensable.

Холодопроизводительность 2,1 кВт~15 кВт
Мощность нагрева 3,5 кВт ~ 15 кВт

Холодопроизводительность 1,8 кВт~200 кВт
Мощность нагрева 3,5 кВт~200 кВт

Холодопроизводительность 0,25 кВт~200 кВт
Мощность нагрева 2,5 кВт~200 кВт

Холодопроизводительность 0,25 кВт~60 кВт
Мощность нагрева 2,5 кВт~60 кВт

Мощность охлаждения 0,3 кВт ~ 80 кВт
Мощность нагрева 3кВт ~ 80кВт
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Мощность охлаждения 0,5 кВт ~ 80 кВт
Мощность нагрева 5,5 кВт ~ 80 кВт
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Мощность охлаждения 0,7 кВт ~ 80 кВт
Мощность нагрева 5,5 кВт ~ 80 кВт
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

Мощность охлаждения 0,4 кВт ~ 1,5 кВт
Мощность нагрева 2 кВт
Medium temp accuracy ±0.5℃
Material temp accuracy ±1℃

WeChat/телефон
86 18914253067

+86 18914253067

Адрес электронной почты
market@lneya.com

Обслужено более 30 000 клиентов.
Экспорт в более чем 20 стран.

Получены сертификаты CE, SGS и ISO

Предоставление комплексного технического обучения.
Круглосуточные решения.

Основана в 2010 году, с 15-летним опытом работы в отрасли.
20% сотрудников — технические специалисты.

Визуальный осмотр.
Тестирование производительности.
Проверка электрической безопасности.
Get in touch with our Chiller Heater Combo experts
Связаться с ЛНЕЙЯ
Отправьте нам свой запрос, и мы свяжемся с вами в течение 24 часов